Report Code Programming

All report codes are entered using #93 Menu Mode Programming , either through Report Code Programming , or through Zone
Programming while entering other zone information. In the VISTA-32FB, reports are divided into six categories. These
categories represent the main menu options in Report Code Programming . Reports and the categories in which they are
found are as follows:
ALARM CODES

Zone Alarm Reports

SYSTEM GROUP #2
Arm STAY
Time Set, Log Reset
Dialer Queue Overflow
Exit Error by Zone
Exit Error by User
Recent Close
The programming sequence that follows assumes that you will be entering all reports for the system at one time. In actuality,
you may skip from one main menu option to another by pressing 0 (N) at each main menu option. Main menu options are
highlighted in bold text. To enter report codes, do the following:
Enter Program Mode: [Installer Code] + 8 0 0. Then press #93. Enter 0 (N) at each main menu option until the Report Code
Programming option is displayed.
PROMPT
REPORT CODE PROG
1 = YES
0 = NO
0
Zone Alarm Reports
PROMPT
ALARM, ID DIGIT?
1 = YES
0 = NO
0
ENTER ZONE NO.
000 = QUIT
001
001 REPORT CODE
1st 00 2nd 00
00
ENTER ZONE NO.
000 = QUIT
001
QUIT REPORT MENU
1 = YES 0 = NO
0
RESTR, SUPV. CODES
(for groups of 16 zones)
Alarm Restore
Trouble
Trouble Restore
Bypass
Bypass Restore
SYSTEM GROUP #3
Early Open
Early Close
Late Open
Late Close
Failed to Open
Failed to Close
Auto-Arm Failed
Schedule Change
EXPLANATION
Press 1 (Y) to enter to Report Code Programming .
EXPLANATION
Press [1] (Y) to enter Alarm Report Codes for zones. Press [0] (N) to skip to the next main menu option.
Enter the zone number for which you are entering the report code.
Press [✱] to continue.
Enter the first digit of the Alarm report code (double-digit entry) and press [✱]. Enter the 2nd digit of the
Alarm Report code.
Press [✱] to continue.
Enter the zone number for which you are entering the report code. When all zone Alarm Codes have been
programmed, enter 000 to Quit.
Press [✱] to continue.
If you have completely finished entering report codes, press [1] (Y) to quit Report Code Programming . If you
wish to enter other system report codes, enter 0 (N).
Press [✱] to continue.
SYSTEM GROUP #1
Closing (arm AWAY)
Opening (disarm)
System Low Battery
Low Battery Restore
AC Loss
AC Restore
Periodic Test
Power
Cancel
Program Tamper
SYSTEM GROUP #4
Fire Walk-Test Start
Fire Walk-Test End
Off-Normal