The purpose of this document is to provide a quick and easy way to program your entire system.
programming procedure is included, followed by a list of program fields with the corresponding program group they belong to
(system-wide, partition-specific, scheduling, etc.). Two program forms are included. One contains all the programming fields,
and the other contains the partition-specific fields. If you are setting up a single-partition system, the partition-specific fields
become system-wide fields.
Following the program forms are system layout worksheets. We recommend that you use these sheets to plan your system
before programming is performed. If you need further information about specific programming options, see the VISTA-32FB
Installation and Setup Guide .
Make sure that one two-line alpha keypad is connected to the control and is set to device address "00."
Single-Partition System
The system default is for a single-partition system. Use the VISTA-32FB SINGLE PARTITION PROGRAMMING FORM
when programming for single-partition usage.
PROCEDURE of this document for proper programming procedure.
Multiple-Partition System
You must enter the number of partitions you are using in data field 2*00 to set the system for multiple partitions. Use the
VISTA-32FB SINGLE PARTITION and the PARTITION-SPECIFIC PROGRAM FORMS when programming the system
for multiple partitions. Follow the steps outlined in RECOMMENDED PROGRAMMING PROCEDURE of this document
for proper programming procedure.
• To enter program mode, enter installer code + [8] + [0] + [0]
• To set standard defaults, press
• To change to next page of program fields, press
• To return to previous set of fields, press
• To erase account and phone number field entries, press [
• To assign zone descriptors, press #93 + follow menu prompts
• To add custom words, press #93 + follow menu prompts
• To enter Installer's Message, press #93 + follow menu prompts
• To exit program mode, enter
✱
98 prevents re-access to programming mode by installer code. The only way to re-access programming
mode is by depressing both the [
Standard default (✱97) values are shown in brackets [ ], otherwise default = 0.
Follow the steps outlined in RECOMMENDED PROGRAMMING
SUMMARY OF PROGRAMMING COMMANDS
✱
97
✱
94
✱
99
✱
✱
✱
99 OR
98:
99 allows re-access to programming mode by installer code.
✱
] and [#] keys at the same time within 30 seconds of power-up.
–5–
✱
✱
] + field number + [
]
A recommended