A A s s s s e e m m b b l l y y a a n n d d P P a a r r t t s s
B B a a r r b b e e d d D D r r a a i i n n E E n n d d C C a a p p A A s s s s e e m m b b l l y y
1
2
93524 Barbed Drain End Cap Assembly:
Main Valve Body. The opening is sealed with an O-ring (1) used as axial or "face" seal. The O-ring sits in a groove
in the End Cap. This groove must be free of defects such as pits or scratches and also free of debris. When
assembling the End Cap to the Valve Body, care should be taken to make sure that the O-ring stays in the groove
in the End Cap. If misaligned, the O-ring can become pinched and leak.
Figure 33: Barbed Drain End Cap Assembly
PART#
DESCRIPTION
93808
O-Ring
93231-2.0
Barbed Drain End Cap
93524
Entire Assembly (all of the above parts)
The Barbed Drain End Cap (2) seals the left opening on the