To program Service settings, press and hold both the P button and the S button while "SERVICE SETTINGS" is
displayed until "Set Lang" is displayed. Programming Service Settings is similar to programming Customer
Settings. The values that can be set are listed below along with available values and comments. (Metric values are
shown in parentheses.)
Note: This section is recommended for qualified service personnel only. The appliance control must be set
correctly for proper performance.
Display
Set Language Eng
Set Language
Units Eng
Units of measure
(Units MET)
Displays the current
Soft v. #0X.XX
software version
Mode 3
Operating (Regeneration) Mode
Hard. Gr. 018
Hardness grains of the water that
(Hard. mg/L 00308)
was tested
Iron ppm 00
Amount of iron in parts per million
(Iron mg/L)
of the water that was tested
Mang. ppm 00
Amount of manganese in parts
(Mang. mg/L 00)
per million of incoming water
Salt=Sodium
Material filling the brine tank
Comp. Hard. 00018
Compensated Hardness
(Comp. Hard. 00308)
Capac. Gr. 07300
The desired capacity number.
(Capac. gm. 0473)
A way to force regeneration at
72-96 hr. Regen Yes
regularly-scheduled intervals.
Number of minutes the first back-
Backwash 1
00.1
wash cycle lasts
Number of minutes the first brine
Brine/Rinse
09.0
and slow rinse cycle lasts
Number of minutes the second
Backwash 2
02.0
backwash cycle lasts
Amount of salt set to be used in
Salt lb.
02.0
each regeneration to achieve the
(Salt kg
00.9)
capacity setting
Used by qualified personnel for
Turbine Test
No
diagnostic purposes
Sets the appliance to regenerate
Reg Tonight
No
tonight
Meaning
Eng=English, Fra=French,
Esp=Spanish
Eng=Gallons (English)
Met=Litres (metric)
X.XX
Timer Mode (Mode 1)
Demand Delayed Mode
(Mode 2)
Demand Immediate Mode
(Mode 3)
03 to 999
00 to 99
00 to 99
Salt=Sodium, Salt=Potassium See SALT WARNING that follows
This parameter cannot be set.
This is the compensated
hardness using the hardness,
iron, and manganese settings.
00000 to 99999 (0000 to 9999)
No (or Yes, for iron)
00.0 to 99.9
00.0 to 99.9
00.0 to 99.9
00.0 to 99.9
No (or Yes—See Warning )
No or Yes
Possible Values
For reference only
See Operating Modes
This is the actual hardness reading and is
not compensated for iron
This value is used to calculate a
compensated hardness automatically
This value is used to calculate a
compensated hardness automatically
The formula used is: Hardness +
(4 x each ppm iron) +
(4 x each ppm manganese) =
compensated hardness
See 72-96 Hour Regeneration that follows
Set to the nearest tenth of a minute
Set to the nearest tenth of a minute
Set to the nearest tenth of a minute
Set to the nearest tenth
WARNING: Do NOT set this to Yes.
If set to Yes, it will force a regeneration at
the next set regeneration time (such as
02:00AM). After the regeneration, the value
will be set to No.
17