Summary of Contents for Hague Quality Water MAXIMIZER 97 Series

  • Page 1 Quality Water International ® ® Version 1.0 Owner’s Manual & Installation Guide...
  • Page 2: Limited Warranty

    Quality Water International ® To place this equipment under warranty, the warranty registration card must be completed and returned by the original owner to Hague Quality Water International within 30 days of installation. Coverage This warranty covers the Hague 97 Maximizer...
  • Page 3: Table Of Contents

    Table of Contents Quality Water International ® Limited Warranty ..........................2 Owner Information ........................4 Maximum Efficiency ........................5 Before You Begin ........................... 6 Checklist Before Installation ......................6 Precautions ............................. 7 Installation ............................8 Installation Steps ........................8-11 Valve Overview ..........................
  • Page 4: Owner Information

    Owner Information Quality Water International ® General Information Congratulations on choosing a superior Hague water treatment appliance! Soon you and your family will be enjoying clean, clear water. Use this guide to attain the maximum benefit from your appliance. As an owner, you may find the first few pages to be the most helpful in solving your needs.
  • Page 5: Maximum Efficiency

    Maximum Efficiency Quality Water International ® Getting Maximum Efficiency From the Appliance To achieve the maximum benefit and performance from this appliance, familiarize yourself with this manual and the appliance. 1. The salt level should always be at least 1/3 full. Refill the salt when the level drops below the water level in the brine cabinet.
  • Page 6: Before You Begin

    Before You Begin Quality Water International ® Checklist Before You Begin (Refer to this checklist before installation) ‰ Water Quality - If the water supply contains sand, sulfur, bacteria, iron bacteria, tannins, algae, oil, acid, or other unusual substances, consider pre-treating the water to remove these contaminants before the water supply enters the appliance, unless the appliance is represented as being capable of treating these contaminants in its specifications.
  • Page 7: Precautions

    Before You Begin Quality Water International ® Precautions 1. Comply with all state and local, building, plumbing, and electrical codes. 2. Install the appliance before the water heater. 3. Install the appliance after the pressure tank on well-water installations. 4. Install a pressure-reducing valve if the inlet pressure exceeds 70 psi (4.8 bar). 5.
  • Page 8: Installation

    Installation Quality Water International ® Installation Steps Step 1 Prepare the Placement Area A. Make sure the placement area is clean. B. Turn off the electricity and water supply to the water heater. For gas water heaters, turn the gas cock to “Pilot.” C.
  • Page 9 Installation Quality Water International ® Installation Steps Step 2 Turn Off Water Supply A. Turn off the water supply. B. Open the hot and cold water taps to depressurize the lines. Step 3 Connect Water Lines A. Connect water lines in compliance with all state and local, building, plumbing, and electrical codes. Step 4 Connect Gravity Overflow Connection The overflow line drains away excess water should the cabinet fill with too much water or the appliance malfunction.
  • Page 10 Installation Quality Water International ® Installation Steps Step 7 Check for Leaks A. Close all faucets. B. Check all lines and connections for leaks. If leaks are found: 1. Turn off the main water supply. 2. Open a cold water faucet to depressurize the lines. 3.
  • Page 11 Installation Quality Water International ® Installation Steps Step 12 Complete the Installation A. Ensure that the bypass is left in the Service position. (see Bypass Valve Overview) B. Ensure the water supply is on. C. Open the inlet valve and turn on the electricity to the water heater. For gas water heaters, return the gas cock to “On.”...
  • Page 12: Valve Overview

    Valve Overview Quality Water International ® Bypass Valve Overview The bypass valve can isolate the appliance should the appliance malfunction or leak. It can also permit the use of untreated water for watering plants, shrubs, or lawns. The bypass valve is attached to the main control valve. See Figure 3. To engage the bypass valve, locate the blue knob on top of the bypass valve.
  • Page 13: Touch Screen Controller

    Smart Touch Controller Quality Water International ® Setting the Touch Screen Controller This appliance features a touch screen controller with a color screen display. The controller can be used to view the appliance’s status, perform regenerations, and change settings. An independent Hague dealer should set the Service Settings during the installation of the appliance.
  • Page 14: Service Settings

    Smart Touch Controller Quality Water International ® Service Settings To program Service Settings on the controller, tap twice on the screen to bring up the “Main Menu”. Follow the following steps to set the Smart Touch controller in the Service Settings. Note: The Service Settings must be set before the Customer Settings.
  • Page 15 Smart Touch Controller Quality Water International ® Iron ppm Manganese ppm Salt Enter Iron test results Enter Manganese test results Select Regenerant (0 to 99 ppm (mg/L)) (0 to 99 ppm (mg/L)) (Sodium or Potassium) “OK” to continue “OK” to continue “OK”...
  • Page 16 Smart Touch Controller Quality Water International ® Salt Monitor Regenerate Tonight Dealer Name Optional salt monitor in use Set to regenerate tonight Enter the (Yes or No) (Yes or No) dealership/business name “OK” to continue “OK” to continue “Ent” to continue Dealer Name Enter the dealership/business phone number...
  • Page 17 Smart Touch Controller Quality Water International ® Visible when Visible when History = Yes History = Yes H-Hardness grains H-Iron ppm H-Manganese ppm Enter hardness test results Enter Iron test results Enter Manganese test results (1 to 199 ppm (mg/L)) (0 to 99 ppm (mg/L)) (0 to 99 ppm (mg/L)) “OK”...
  • Page 18: Customer Settings

    Smart Touch Controller Quality Water International ® Customer Settings To program Customer Settings on the controller, tap twice on the screen to bring up the “Main Menu”. Follow the following steps to set the Smart Touch controller in the Customer Settings. Note: The Service Settings must be set before the Customer Settings.
  • Page 19: Operating Modes

    Operating Modes Quality Water International ® Smart Touch Operating Modes The controller has a Timer mode (Mode 1 Frequency and Mode 1 Days of the Week), a Demand Delayed mode (Mode 2), and a Demand Immediate mode (Mode 3). These modes are equipped with Capacity Guard , which ensures that a ®...
  • Page 20: Mode Setting Chart

    Mode Setting Chart Quality Water International ® Mode Setting Chart This section provides guidance for using different service settings to achieve the desired capacity. 97 Maximizer 97MM Mode 1 and Mode 2 Regeneration Frequency Mode 1 only 96 hour regeneration (if iron present—yes) Yes or No #1 Salt Setting Backwash 1 (minutes)
  • Page 21: Assembly And Parts

    Assembly and Parts Quality Water International ® Cabinet and Cover Incorrect Correct Figure 4: Cabinet and Cover Assemblies Figure 5: Controller Tab Lock Detail Part # Description Qty. 97004 Cover Assembly 54490 Touch Controller 90837 Bypass Nut Gasket 90259 1-inch CPVC CTS Adapter 90254 3/4-inch Copper Adapter (optional) 90256...
  • Page 22: Cabinet And Assemblies

    Assembly and Parts Quality Water International ® Cabinet and Assemblies Figure 6: Cabinet and Assemblies Part # Description Qty. 54611 Bypass Valve Assembly 54320 Turbine Axle 90522 Turbine Assembly 93838 O-Ring - IO Adapter 97500 Media Tank Assembly 97005 97MM Support Panel - Black 90828 O-Ring - Small End Cap 90819...
  • Page 23: Injector

    Assembly and Parts Quality Water International ® Injector INSERT WITH RIB AT 9 O’CLOCK POSITION Figure 7: Injector Assembly Part # Description Qty. Note In conjunction with the injector nozzle it creates the vacuum that draws the brine solution from the brine cabinet. The center hole should be clear of debris, 93223 Injector Throat round, and undamaged.
  • Page 24: Bypass Valve

    Assembly and Parts Quality Water International ® Bypass Valve Figure 8: Bypass Valve Assembly Part # Description Qty. Note Makes the connection between the plumbing and the appliance. The bypass valve assembly allows water to bypass the appliance for service or when untreated water is desired. The recommended seal for the 1-1/4-inch male inlet-outlet threads is the plastic bypass nut (90251), O-Ring (90837), and 1-inch CPVC CTS adapter (90259).
  • Page 25 Assembly and Parts Quality Water International ® Bypass Valve Part # Description Qty. Note 90827 O-Ring The dial permits the addition of “untreated water” into the soft water 90252 Blending Dial outlet. It is closed when pointing toward the main control valve and open when pointing toward the inlet side.
  • Page 26: Drive End Cap

    Assembly and Parts Quality Water International ® Drive End Cap Figure 9: Drive End Assembly Part # Description Qty. Note 90802 Screw The motor is held in place by two 1/2-inch self-tapping screws. The screws should be “snug.” The brass pinion gear on the motor 90217 Drive Motor should engage the plastic drive gear.
  • Page 27 Assembly and Parts Quality Water International ® Drive End Cap Part # Description Qty. Note Seals the two openings on the main control valve. The larger diameter opening is sealed with an O-Ring used as an axial or “face” seal. The O-Ring sits in a groove in the end cap. This groove must be free of defects such as pits or scratches and also free of debris.
  • Page 28: Brine Valve Housing

    Assembly and Parts Quality Water International ® Brine Valve Housing Figure 11: Brine Valve Housing Assembly Part # Description Qty. Note The piston should have an O-Ring on the shaft side of the Piston Assembly flange and a spring pressed onto a boss on the other side. 53511 (includes O-Ring &...
  • Page 29: Drain End Cap

    Assembly and Parts Quality Water International ® Drain End Cap Figure 12: Drain End Cap Assembly Part # Description Qty. Note 90614 - 2.4 Drain End Cap Assembly Entire Assembly 90614 - 3.0 Drain End Cap Assembly Entire Assembly (Optional for 97MMB1 or 97MMP1 only) 90819 O-Ring The drain end cap seals the left opening on the main control...
  • Page 30: Safety Shutoff

    Assembly and Parts Quality Water International ® Safety Shutoff Part # Description Qty. 54900 Entire Safety Shutoff Assembly 54226 Safety Shutoff 56018 Float 54190 Air Check/Draw Tube Figure 13: Safety Shutoff Assembly Maximizer 97 Owner’s Manual OR-05/18/15 ®...
  • Page 31 Assembly and Parts Quality Water International ® Safety Shutoff Valve Elbow 3/8" Poly Tube 3/8" Plastic Gripper 3/8" Nut 3/8" Plastic Insert 3/8" Retainer Sleeve Wrist Pin Hex Nut 1/2" Nut Aircheck/draw Tube Figure 14: Safety Shutoff Valve Elbow Assembly Part # Description Qty.
  • Page 32: Troubleshooting

    Troubleshooting Quality Water International ® Troubleshooting Problem Possible Cause Solution No salt in brine cabinet Add salt Remove the brine line and flush clean Sediment in brine cabinet has plugged the Remove the air check/draw tube and flush with brine line and air check/draw tube clean water.
  • Page 33 Troubleshooting Quality Water International ® Troubleshooting Problem Possible Cause Solution Make sure the controller is pushed all the way Controller not attached properly onto the drive end cap Defective magnet disk Replace magnet disk Appliance Stays In Regeneration Remove foreign object(s) from the main control Foreign object in main control valve valve Broken valve assembly.
  • Page 34 Notes Quality Water International ® Notes Maximizer 97 Owner’s Manual OR-05/18/15 ®...
  • Page 35: Specifications

    Specifications Quality Water International ® Water Conditioner Specifications Maximizer Model 97 97MM ® Max Compensated Hardness - gpg (g/L) 90 (1540) Maximum ferrous iron reduction - ppm Minimum pH - standard units Filtration - nominal rating - microns 1.0 (28) Media Amount - cu.
  • Page 36 Quality Water International ® Made In Hague Quality Water International 4343 S Hamilton Road 614.836.2115 Groveport, OH 43125 www.haguewater.com ©2015 97905 Version 1.0 OR-05/18/15...

This manual is also suitable for:

Maximizer 97mmMaximizer 97mmb1Maximizer 97mmp1

Table of Contents