Technical information
8.4 Technical specifications
Interfaces
DVI-I
DisplayPort
Keyboard
Mouse
USB
PROFIBUS / MPI interface,
isolated
- Transmission speed
- Operating modes
PROFINET
Ethernet
COM1
Free slots for expansion
cards
For unique labeling, the Ethernet ports are numbered on the enclosure. The numbering by the
3
operating system can differ.
No teaming with AMT.
4
When using AMT, the interface x1 p1 must be used for connection to remote maintenance.
5
124
Connection of DVI display devices
Connection of DisplayPort display devices
USB support
USB support
4 × USB 3.0, a maximum of 2 can be operated in high-current mode
at the same time
Front USB 3.0 for device with resistive single touch
9-pin Cannon socket, 2-row
9.6 kbps to 12 Mbps
DP master: DP-V0, DP-V1 with SOFTNET-DP
DP slave: DP-V0, DP-V1 with SOFTNET-DP slave
RJ45 connector, CP1616 compatible, on-board interface on ERTEC
3
400 basis, 10/100 Mbps electrically isolated
2 × Ethernet port (RJ45) Intel WGI217LM and
3
Intel WGI210IT10/100/1000 Mbps, electrically isolated
Wake on LAN, Remote Boot, teaming and Jumboframes up to 9014
bytes are supported
RS232, 115 kbps max., 9-pin SUB-D, male
2 PCI/PCIe cards
4 5
Operating Instructions, 09/2014, A5E32995420-AC