Stray Welding Currents - EWM Taurus 351 Basic FKG Operating Instructions Manual

Hide thumbs Also See for Taurus 351 Basic FKG:
Table of Contents

Advertisement

Design and function
Transport and installation
Fully unroll welding current leads, torch hose packages and intermediate hose packages. Avoid
loops!
Always keep leads as short as possible!
Lay any excess cable lengths in meanders.
5.1.7

Stray welding currents

Risk of injury due to stray welding currents!
Stray welding currents can destroy protective earth conductors, damage machines and
electronic devices and cause overheating of components, leading to fire.
Check that all welding current connections are firmly secured and electrical connections are
in perfect condition.
Set up, attach or suspend all conductive power source components such as casing,
transport vehicles and crane frames so they are insulated.
Do not place any other electronic devices such as drills or angle grinders on the power
source, transport vehicle or crane frames unless they are insulated.
Always put welding torches and electrode holders on an insulated surface when they are
not in use.
26
Figure 5-4
WARNING
Figure 5-5
099-005425-EW501
14.07.2016

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taurus 401 basic fkgTaurus 351 basic fkwTaurus 401 basic fkwTaurus 501 basic fkw

Table of Contents