Design and function
Machine configuration menu
1 Preparation
•
Switch off the welding machine.
•
Unscrew the gas nozzle from the welding torch.
•
Trim the welding wire so that it is flush with the contact tip.
•
Retract the welding wire a little (approx. 50 mm) on the wire feeder. There should now be no more
welding wire in the contact tip.
2 Configuration
•
Press the "Welding procedure" push-button while simultaneously switching on the welding machine.
Release push-button.
•
The required parameter can now be selected using the 'Welding parameter setting' rotary knob.
Parameter rL1 must be adjusted for all machine combinations.
3 Alignment/measurement
•
Applying slight pressure, put the welding torch in place with the contact tip on a clean, purged location
on the workpiece and then press the torch trigger for approx. 2 seconds. A short-circuit current will
flow briefly, which is used to determine and display the cable resistance. The value can be between
0 mΩ and 40 mΩ. The new value is immediately saved without requiring further confirmation. If no
value is shown on the right-hand display, then measurement failed. The measurement must be
repeated.
4 Restoring welding standby mode
•
Switch off the welding machine.
•
Screw the gas nozzle onto the welding torch.
•
Switch on the welding machine
•
Insert the welding wire.
56