5.3.32 Tone Settings
Description
Value Range
Default Value
BUSY_TONE_RPT
Value Format
Description
Value Range
Default Value
BUSY_TONE_TIMING
Value Format
Description
Value Range
Default Value
Web User Interface Reference
REORDER_TONE_FRQ
Value Format
Description
Value Range
Default Value
Web User Interface Reference
286
Administrator Guide
Specifies the gain, in decibels, of the busy tone.
-24–24 (dB)
0
INTEGER
Specifies whether the busy tone is repeated.
0–1
–
0: No Repeat
–
1: Repeat
1
Comma-separated Integer
Specifies the pattern, in milliseconds, of busy tones using up to 10
whole numbers (off 1, on 1, off 2, on 2...) separated by commas.
Note
•
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
0–16000 (0: Continuous)
Note
•
Avoid setting 1–50 for any of the values.
60,330,270
Tone Timings (Page 149)
Comma-separated Integer
Specifies the dual-tone frequencies, in hertz, of reorder tones using 2
whole numbers separated by a comma.
0, 200–2000 (0: No tone)
425,0
Tone Frequencies (Page 150)
Document Version 2015-12