5.3.24 CODEC Settings
Value Format
Description
Value Range
Default Value
Web User Interface Reference
CODEC_PRIORITYx_n
Parameter Name Example
Value Format
Description
Value Range
262
Administrator Guide
BOOLEAN
Specifies whether to enable the codec specified in the parameter list.
Note
•
The "x" character in the parameter title should be changed to
one of the following numbers, according to the codec to be
changed.
–
0: G.722
–
1: PCMA
–
3: G.729A
–
4: PCMU
•
For codec setting examples, see 2.5.1 Examples of Codec
Settings.
•
Y (Enable)
•
N (Disable)
•
CODEC_ENABLE0_n="N"
•
CODEC_ENABLE1_n="N"
•
CODEC_ENABLE3_n="Y"
•
CODEC_ENABLE4_n="N"
•
G.722 (Enable) (Page 130)
•
PCMA (Enable) (Page 131)
•
G.729A (Enable) (Page 131)
•
PCMU (Enable) (Page 132)
CODEC_PRIORITYx_1, CODEC_PRIORITYx_2
INTEGER
Specifies the priority order for the codec.
Note
•
The "x" character in the parameter title should be changed to
one of the following numbers, according to the codec to be
changed.
–
0: G.722
–
1: PCMA
–
3: G.729A
–
4: PCMU
•
For codec setting examples, see 2.5.1 Examples of Codec
Settings.
1–255
Document Version 2015-12