4.7.1 Provisioning Maintenance
4.7.1.1 Provisioning Maintenance
Standard File URL
Description
Value Range
Default Value
Configuration File Reference
Product File URL
Description
Value Range
Default Value
Configuration File Reference
Master File URL
Description
Value Range
Default Value
Configuration File Reference
Cyclic Auto Resync
Description
Value Range
Default Value
Configuration File Reference
Resync Interval
Description
Value Range
154
Administrator Guide
Specifies the URL of the standard configuration file, which is used when
every unit needs different settings.
Max. 384 characters
Not stored.
CFG_STANDARD_FILE_PATH (Page 189)
Specifies the URL of the product configuration file, which is used when
all units with the same model number need the same settings.
Max. 384 characters
Not stored.
CFG_PRODUCT_FILE_PATH (Page 189)
Specifies the URL of the master configuration file, which is used when
all units need the same settings.
Max. 384 characters
Not stored.
CFG_MASTER_FILE_PATH (Page 189)
Selects whether the unit periodically checks for updates of configuration
files.
•
Yes
•
No
No
CFG_CYCLIC (Page 189)
Specifies the interval, in minutes, between periodic checks for updates
of the configuration files.
1–40320
Document Version 2015-12