Initializing The E, F, 7 Page Data; Modification Of E, F, 7 Page Data - Sony DCR-PC100 Service Manual

Hide thumbs Also See for DCR-PC100:
Table of Contents

Advertisement

3. B Page Table
Note: Fixed data-1: Initialized data. (Refer to "1. Initializing the B Page
Data".)
Fixed data-2: Modified data. (Refer to "2. Modification of B Page
Data".)
Address
Remark
00 to F9
Fixed data-1
(Initialized data)
FA
Fixed data-2
(Modified data. Copy the data built in the same
model.)
FB to FF
Fixed data-1
(Initialized data)
Table. 5-1-4.
1-2-4.
INITIALIZATION OF E, F, 7 PAGE DATA
Switch setting
POWER .................................................................. CAMERA

1. Initializing the E, F, 7 Page Data

Note: If the E, F, 7 page data has been initialized, following adjustments
need to be performed again.

1) Modification of E, F, 7 page data

2) Camera system adjustments
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Note1: For the camera microprocessor ver. 1.0 or ver. 2.0.
Note2: For the camera microprocessor ver. 3.0 or later.
Note3: Refer to "3. Modification of F Page Data" for the camera
microprocessor version.
Initializing Method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 01, and set data: 2D (NTSC) or data:
2F (PAL): and press the PAUSE button of the adjustment remote
commander.
3)
Select page: 6, address: 03, set data: 01, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 6, address: 02, and check that the data is "01".
5)
Perform "Modification of E, F, 7 Page Data" and "Modification
of F Page Data".
2. Modification of E, F, 7 Page Data
If the E, F, 7 page data has been initialized, change the data of the
"Fixed data-2" address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
5-13
F
10 to FF
E
00 to FF
7
00 to 4D (Note1)
00 to 67 (Note2)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-pc100e