Initialization Of B Page Data - Sony DCR-PC100 Service Manual

Hide thumbs Also See for DCR-PC100:
Table of Contents

Advertisement

Initial value
Address
NTSC PAL
76
Fixed data-2
77
Fixed data-1
78
Fixed data-2
79
(Modified data. Copy the data built in
the same model.)
7A
90
90
Bright adj.(EVF)
7B
80
80
Contrast adj.(EVF)
7C
Fixed data-1
7D
(Initialized data)
7E
7F
80
9E
9E
White balance adj.(LCD)
81
80
80
82
74
74
Black limit adj.(LCD)
83
88
88
Gamma1 adj.(LCD)
84
70
70
VCO adj.(LCD)
85
88
88
Center level adj.(LCD)
86
Fixed data-1
87
Fixed data-2
88
(Modified data. Copy the data built in
89
the same model.)
8A
90
90
Bright adj.(LCD)
8B
Fixed data-2
8C
B7
B7
Contrast adj.(LCD)
8D
Fixed data-2
8E
8F
Fixed data-1
90
Fixed data-2
91
Fixed data-1
92
(Initialized data)
93
94
Fixed data-2
95
(Modified data. Copy the data built in
96
the same model.)
97
98
Fixed data-1
99
(Initialized data)
9A
9B
9C
9D
9E
Fixed data-2
9F
Fixed data-1
Table. 5-1-3.
Remark
1-2-3.

INITIALIZATION OF B PAGE DATA

Note: When reading the B page data, insert a "Memory Stick" into the
"Memory Stick" slot.
Switch setting
POWER ................................................................. MEMORY
1. Initializing the B Page Data
Note: If the B page data has been initialized, the following adjustments
need to be performed again.
1) Modification of B page data
Adjusting page
Adjusting Address
Initializing Method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 2, address: 8F, set data: 03, and press the PAUSE
button.
3) Select page: 2, address: 8F, set data: 02, and press the PAUSE
button.
4) Select page: 2, address: 8F, set data: 00, and press the PAUSE
button.
5) Select page: 5, address: 01, set data: F3, and press the PAUSE
button.
6) Select page: 5, address: 00, set data: 01, and press the PAUSE
button.
7) Select page: 5, address: 01, and wait for three seconds.
8) Select page: 5, address: 00, and check that the data is "00".
9) Select page: 5, address: 02, and check that the data is "00".
10) Perform "Modification of B Page Data".
2. Modification of B Page Data
If the B page data has been initialized, change the data of the "Fixed
data-2" address shown in the following tables by manual input.
Processing before Modification of B Page data
1) Select page: 2, address: 8F, set data: 03, and press the PAUSE
button.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of B Page data
1) Select page: 2, address: 00, and set data: 29.
2) Select page: 2, address: 01, and set data: 29, and press the
PAUSE button of the adjustment remote commander.