10. MAX GAIN Adjustment

Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject
Clear chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
1D, 8C, 9E, 9F
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Preparation before adjustment
1)
Select page: 6, address: 0A, and check the data.
• If the data is "D0" to "FF".
Perform "Adjustment method (1)".
• If the data is "00" to "CF".
Perform "Adjustment method (2)".
Adjusting method (1):
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to each address.
Note: Press the PAUSE button of the adjustment remote commander
each time to set the data.
Address
Data
1D
80
8C
02
9E
00
9F
00
Adjusting method (2):
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 1D, set data: 78 (NTSC) or 88 (PAL),
and press the PAUSE button.
3)
Select page: 6, address: 96, and set data: 00 (NTSC) or 40
(PAL).
4)
Select page: 6, address: 97, and set data: 23 (NTSC) or 13 (PAL).
5)
Select page: 6, address: 01, set data: 6F, and press the PAUSE
button of the adjustment remote commander.
(The MAX GAIN adjustment is performed and the adjustment
data is stored in page: F, address: 1D.)
6)
Select page: 6, address: 02, and check that the data is "01".
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2)
Select page: 6, address: 96, and set data: 00.
3)
Select page: 6, address: 97, and set data: 00.
4)
Select page: 0, address: 01, and set data: 00.
11. Auto White Balance & LV Standard Data Input
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: This adjustment should be carried out upon completion of "Color
Reproduction Adjustment".
Note2: Check that the data of page: 6, address: 02 is "00". If not, turn off
the power and turn on again.
Note3: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu display) ................................... OFF
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 01, set data: 11, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 6, address: 01, set data: 0D, and press the PAUSE
button.
(When the standard data is take in, the data will be automatically
input to page: F, address: 1E, 1F, 30 to 33.)
4)
Select page: 6, address: 02, and check that the data is "01".
Checking method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 10, set data: 2E, and press the PAUSE
button.
3)
Select page: 1, and check that the display data (Note3) satisfies
the specified value.
Processing after Completing Adjustments:
1)
Select page: F, address: 10, set data: 00, and press the PAUSE
button.
2)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 0, address: 01, and set data: 00.
4)
Perform "Auto White Balance Adjustment".
5-27
Clear chart
(Color reproduction adjustment frame)
Display data of page 1 (Note3)
Adjustment remote commander
F
1E, 1F, 30 to 33
0FF0 to 1010
Display data