Outdoor Unit
2.7
Removal of
Procedure
Step
1. Remove the PCB.
Feature of the PCB
1
2
Loosen the screw on
the terminal board.
Release the earth
3
terminal.
156
PCB
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
SiBE06-514A
Points
You can remove the PCB
when you disconnect the
read wires on the terminal
board without removing the
electrical box.
PbF (Pb free brazing) is
adopted.