Removal Of The Horizontal Blade - Daikin FVKS25BVMB Service Manual

Inverter pair floor standing type b-series
Hide thumbs Also See for FVKS25BVMB:
Table of Contents

Advertisement

SiBE06-514A
1.2
Removal of the
Procedure
Step
Open the horizontal
1
blade.
Undo the supporting
2
bracket at the center
position.
Bend the horizontal
3
blade slightly to undo
the shafts at left and
right side of the blade.
Removal Procedure
Horizontal Blade
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work
Procedure
Indoor Unit
Points
For installation, engage the
supporting bracket at center
of the blade after insert the
shafts at both ends to the
pivot holes.