Features
A
i t
y
B
U n
S k
V M
B A
r
t
d o o
1 0 A
S -
l i
F V X
S p
I n
R 4
Compact&stylish
Lightweight and compact
Can be used as a floor standing or lower wall application. As a floor
standing model, it can be semi-recessed or fully recessed without
1
loss of capacity.
A double horizontal air outlet ensures uniform air flow and
1
temperature distribution
The home leave operation saves energy during absence
Air purification filter: deodorises the air and helps to prevent bacterial
and viral propagation
The photocatalytic deodorising air filter: powerfully decomposes
cigarette and pet odours, removes house dust and pollen and
deactivates bacteria and viruses
Powerful mode can be selected for rapid cooling or heating
1
• Indoor Units • R410A • FVXS-BAVMB
standard
• Split Sky Air • Indoor Units
Washable front panel
Indoor unit silent operation: "Silent" button on the remote control
lowers the operation sound of the indoor unit by 3dB(A).
Easy to install
Up to 4 indoor units can be connected to 1 Multi outdoor unit. All
indoor units are individually controllable with remote control and do
not need to be installed in the same room or at the same time. They
operate simultaneously within the same cooling operation
Daikin remote controls give you easy control at your fingertips.
The remote control has a 24-hour timer
The indoor unit also has a start/stop button mounted on the front
panel
Up to 5 indoor units can be operated from a single centralised control
Purpose-designed holder provided for your remote control
optional
MXS
5 steps

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FVXS25BAVMB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daikin FVXS25BAVMB

  • Page 1 • The home leave operation saves energy during absence • Daikin remote controls give you easy control at your fingertips. • Air purification filter: deodorises the air and helps to prevent bacterial and viral propagation •...
  • Page 2: Specifications

    • Indoor Units • R410A • FVXS-BAVMB Specifications 2-1 FOR INDOOR UNITS ONLY FVXS25BAVMB FVXS35BAVMB FVXS5 0BAVMB Nominal Input Cooling 0.032 0.032 0.055 Heating 0.032 0.032 0.070 2-2 TECHNICAL SPECIFICATIONS FVXS25BAVMB FVXS35BAVMB FVXS5 0BAVMB Casing Colour Almond white Dimensions Packing...
  • Page 3 • Indoor Units • R410A • FVXS-BAVMB Specifications 2-2 TECHNICAL SPECIFICATIONS FVXS25BAVMB FVXS35BAVMB FVXS50BAVMB Motor Output (high) Cooling Sound Power High 54.0 55.0 56.0 Sound High 38.0 39.0 44.0 Pressure Medium 32.0 33.0 40.0 26.0 27.0 36.0 Silent 23.0 24.0 33.0...
  • Page 4 • Indoor Units • R410A • FVXS-BAVMB Specifications 2-3 ELECTRICAL SPECIFICATIONS FVXS25BAVMB FVXS35BAVMB FVXS5 0BAVMB Voltage range Minimum -10% Maximum +10% Power Supply Intake Outdoor unit only • Split Sky Air • Indoor Units...
  • Page 5 KAF925B42 Anti-theft protection for remote control KKF917A4 (1) Wiring adapter is supplied by Daikin. Time clock and other devices; field supply. (2) Wiring adapter is also required for each indoor unit. (3) For DIII-NET adapter • Split Sky Air • Indoor Units...
  • Page 6: Control Systems

    • Indoor Units • R410A • FVXS-BAVMB Control systems FVK/XS-B <ARC433A5, A6> Signal transmitter: OUTDOOR UNIT SILENT button: • It sends signals to the indoor unit. SILENT operation Display: FAN setting button: • It displays the current settings. (In this illustration, each •...
  • Page 7: Dimensional Drawing & Centre Of Gravity

    • Indoor Units • R410A • FVXS-BAVMB Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing unit (mm) FVK/XS25-35-50B Terminal strip with earth terminal Operation lamp 620 (half concealed) Liquid pipe (J6.4 CuT) Timer lamp Note) 1. The mark (Y) shows piping direction Gas pipe (AA CuT) Indoor unit ON/OFF switch Front panel fixed screws (inside)
  • Page 8: Centre Of Gravity

    • Indoor Units • R410A • FVXS-BAVMB Dimensional drawing & centre of gravity 5 - 2 Centre of gravity 4D036467 • Split Sky Air • Indoor Units...
  • Page 9: Piping Diagram

    • Indoor Units • R410A • FVXS-BAVMB Piping diagram FVK/XS25-35B Indoor unit Heat exchanger Fan motor Cross flow fan Thermistor on heat exchanger Fan motor Cross flow fan Field piping Single union joint Field piping Single union joint Refrigerant flow Cooling Heating 4D034714A...
  • Page 10: Wiring Diagram

    • Indoor Units • R410A • FVXS-BAVMB Wiring diagram 7 - 1 Wiring diagram FVK/XS25-35-50B Outdoor Transmission circuit Infrared remote Field wiring control : Protective earth : Fuse Signal H1P,H2P,H3P : Pilot lamp receiver : Limit switch M1F,M2F : Fan motor : Swing motor : Lower air outlet motor PCB1∼PCB4 : Printed circuit board...
  • Page 11: Sound Data

    • Indoor Units • R410A • FVXS-BAVMB Sound data 8 - 1 Sound level data Cooling only Sound pressure level 230V, 50Hz Sound power level Model cooling Cooling Measuring location Location of microphone FVKS25B FVKS35B FVKS50B Heat pump Sound pressure level 230V, 50Hz Sound power level Model...
  • Page 12: Sound Pressure Spectrum

    • Indoor Units • R410A • FVXS-BAVMB Sound data 8 - 2 Sound pressure spectrum FVXS25B (Cooling) FVXS35B (Cooling) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 3D035249A Octave band center frequency (Hz) NOTES 3D035250A Octave band center frequency (Hz) Operation sound is measured in an anechoic chamber.
  • Page 13 • Indoor Units • R410A • FVXS-BAVMB Sound data 8 - 2 Sound pressure spectrum FVXS50B (Heating) FVXS35B (Heating) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 3D035251A Octave band center frequency (Hz) 3D035250A Octave band center frequency (Hz) NOTES NOTES Operation sound is measured in an anechoic chamber.
  • Page 14: Installation Method

    • Indoor Units • R410A • FVXS-BAVMB Installation 9 - 1 Installation method The indoor unit may be mounted in any of the three styles shown here. Half concealed Concealed Exposed Grid (field supply) Front panel 70 mm or more Air filter 50 mm or more from walls (on...