Scheduled Maintenance Inspections - Skyjack SJ 3215 Service Manual

Scissor lifts
Hide thumbs Also See for SJ 3215:
Table of Contents

Advertisement

Service and Maintenance
High Speed
Limit Switch
CONVENTIONALS

1.1 Scheduled Maintenance Inspections

Begin the scheduled maintenance inspections by
checking each item in sequence for the conditions listed
in this section.
wARNiNG
To avoid injury, do not operate an aerial
platform until all malfunctions have been
corrected.
wARNiNG
To avoid possible injury, ensure aerial
platform power is off during your visual
and daily maintenance inspections.
Electrical
Maintaining the electrical components is essential
to good performance and service life of the aerial
platform.
Inspect the following areas for chafed, corroded and
loose wires:
• base to platform cables and wiring harness
• battery tray wiring harnesses
• hydraulic/electrical wiring harnesses
SKYJACK, Page 18
Section 1 - Scheduled Maintenance
High Speed
Limit Switch
Pothole Protection
Limit Switch
COMPACTS
Hydraulic
Maintaining the hydraulic components is essential
to good performance and service life of the aerial
platform.
Perform a visual inspection around the following
areas:
hoses and fittings
all hydraulic cylinders
all hydraulic manifolds
the underside of the base
ground area under the aerial platform
1.1-1 Labels
Refer to the labels section in this manual and determine
that all labels are in place and are legible.
1.1-2 Limit Switches
Detecting limit switch malfunction is essential to safe
aerial platform operation. Ensure limit switches are
properly secured and movement is not obstructed.
Visually inspect all limit switch located inside the scissor
arms and the outrigger assemblies for the following:
• broken or missing actuator arm
• missing fasteners
• loose wiring
SJIII Series

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sj 3219

Table of Contents