Condition Channels - Bosch MS 6 Manual

Engine control unit
Hide thumbs Also See for MS 6:
Table of Contents

Advertisement

Bosch Motorsport
▪ At power‐up, the reset value (10) is used for 'p_br_front_mx'.
▪ 'p_br_front' rises to 30. As 'p_br_front' is > 20 (condition is TRUE), the condi‐
tion 'max (p_br_front, p_br_front_mx)' in the THEN window is triggered. The
condition sets the bigger value as new value for 'p_br_front_mx'. As
'p_br_front' (30) is bigger than 'p_br_front_mx' (10), the new value for
'p_br_front_mx' is set to 30.
▪ Although 'p_br_front' falls to 25, the value of 'p_br_front_mx' stays 30. This is
caused by the THEN‐condition, because p_br_front_mx' (30) is still bigger
than p_br_front' (25).
▪ As 'p_br_front' rises to 40. As 'p_br_front' (40) is bigger than 'p_br_front_mx'
(30), the new value for 'p_br_front_mx' is set to 40.
▪ As 'p_br_front' falls below 20, the IF‐condition turns to FALSE. Now the OTH‐
ERWISE‐condition is triggered. Because the condition 'p_br_front_mx' sets the
value of 'p_br_front_mx' and the value that is already set to 40 before, noth‐
ing changes.
▪ When 'p_br_front' rises to 40, the IF‐condition changes to TRUE again and
triggers the THEN‐condition. Now the reset value (10) is used for
'p_br_front_mx' in the THEN‐condition.
▪ Because 40 is bigger than 10 the new value of 'p_br_front_mx' is 40.
6.3

Condition Channels

▪ Logical operations on measurement channels
▪ If – Else structure with reset
▪ Logical result
▪ Result can be used as input source for further calculations in the whole
project
Follow the steps shown in the screenshot.
1st: Double-click
on 'Conditional
Channels' in
Project Tree
2nd: Click on
'Add condition'
ECU MS 6
Project Configuration | 6
53 / 78

Hide quick links:

Advertisement

Table of Contents
loading