Project Configuration; Math Channels - Bosch MS 6 Manual

Engine control unit
Hide thumbs Also See for MS 6:
Table of Contents

Advertisement

6 | Project Configuration

50 / 78
6
Project Configuration
6.1

Math Channels

▪ Arithmetic and logical operations on up to 4 measurement channels
▪ Numerical results
▪ Result can be used as input source for various calculations in the whole
project
Double click "Math Channels" in MS 6 logger and display project tree.
The 'Create/edit math channel' window appears. Define the math channel using
the following configuration possibilities:
a)
b)
c)
d)
e)
a) Enter the name of the math channel.
b) Enter a description of the math channel.
c) Enter the formula.
d) Select the logical operator.
e) Choose a measurement channel.
Click 'Finish' when done. The math channel is displayed in the MS 6 math chan‐
nel window.
f) Define a value that can be used as a constant in the formula.
g) Choose a function.
h) Describes the function selected above.
ECU MS 6
f)
g)
h)
Bosch Motorsport

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents