Completing the Replacement

Go to the section that represents your configuration, and follow the steps to complete the
replacement:

Both Nodes Running G5.1.0

G5.1.0 on mg-b and G5.2.0 or Higher on mg-a

Both Nodes Running G5.2.0 or Higher

Both Nodes Running G5.1.0
If both your existing Memory Gateway node (mg-b) and the newly replaced Gateway node are both
running software version G5.1.0, complete the following steps:
While logged in to the newly replaced Memory Gateway node, enter the following command:
1.
mg-a [violin: master]# cluster id <same_id_as_mg-b>
Watch the command line to ensure that the prompt changes to
2.
G5.1.0 on mg-b and G5.2.0 or Higher on mg-a
If your existing Memory Gateway node (mg-b) is running software version G5.1.0 and the newly
replaced Gateway node is running G5.2.0 or higher, contact HP Customer Support.
Both Nodes Running G5.2.0 or Higher
If both your existing Memory Gateway node (mg-b) and the newly replaced Gateway node are both
running software version G5.2.0, complete the following steps:
While logged in to the newly replaced Memory Gateway node, enter the following command at the
1.
prompt:
mg-a [violin: master]# no cluster enable
Next, enter this command after the prompt:
2.
mg-a [violin: master]# fms enable
The prompt changes to look like the following:
mg-a [FRU: searching](config)#
AM456-9025A
on page 41
HP VMA SAN Gateway Installation and Configuration Guide
on page 41
on page 41