The configuration wizard displays the HP VMA SAN Gateway cluster settings, as shown in the
following example, then exits to the CLI.
You have entered the following information:
1. Configure as master/stand-alone: yes
2. Public interface name: eth1
3. Public interface IP address: 10.1.14.200
4. Public interface netmask: 255.255.252.0
5. Global default gateway: 10.1.12.1
6. DNS server name(s): 10.1.12.5
7. Domain name: my.storageco.int
8. Hostname: my-gateway1
9. Set clock timezone: yes
10. Zone to use: America
11. Sub-zone 1 to use: North
12. Sub-zone 2 to use: United_States
13. Sub-zone 3 to use: Pacific
14. NTP server name(s): 10.1.1.5,10.1.12.5
15. Email Notification recipient(s): admin@mystorageco.com
16. Email mailhub: 10.1.6.20
17. Email mailhub port: 25
18. Enable Violin support: yes
19. Admin password (Enter to leave unchanged): (unchanged)
20. Cluster interface name: eth1
21. Cluster expected nodes: 1
22. Cluster id: 99999-9999-1107
23. Cluster name: gateway-cluster1
24. Cluster mgmt IP address and masklen: 0.0.0.0
To change an answer, enter the step number to return to.
Otherwise hit <enter> to save changes and exit.
Choice:
Configuration changes saved.
To return to the configuration wizard after exiting, enter the command
6.
jump-start
The configuration jump-start command should only be used during the initial
Caution:
installation of a specific gateway.
28
in the CLI.
HP VMA SAN Gateway Installation and Configuration Guide
configuration
AM456-9025A

Advertisement

Table of Contents
loading

Table of Contents