2. Carefully pull the module out of the chassis.
E.3.4.2
Replacement Procedures
1. Slide the module straight into the open slot until it engages with the backplane
connector.
2. Push the arms in until they lock in place.
3. Make sure the module is operating and the Status LED(s) is green.
E.3.5

Management Module Replacement

FRU part number:
• 12800MM01
E.3.5.1
Removal Procedures
1. Loosen the thumbscrew until it releases from the faceplate.
2. Pull the release arm out until the management module disengages from the
backplane connector.
Figure 77.
12800 Management Module Removal
3. Carefully pull the module out of the chassis.
E.3.5.2
Replacement Procedures
1. Slide the module straight into the open slot until it engages with the backplane
connector.
2. Move the release arm in until it locks in place.
3. Tighten the thumbscrew.
4. Make sure the module is operating and the Module Status, Chassis Status and
MRL Active LEDs are green.