Accessible drives
V
CAUTION!
Keep the dummy module for future use. If the drive is removed again
and not replaced with a new drive, the dummy module must be
reinstalled due to cooling, to comply with applicable EMC regulations
(regulations on electromagnetic compatibility) and to protect against
fire.
Ê Unpack the new drive, and make the desired settings. You should read the
accompanying documentation supplied with the drive beforehand.
Figure 8: Attaching the rails to the CD/DVD drive
Ê Press the EasyClick rails into the lower mounting holes of the drive. Screws
are not necessary, the pins at the rails engage into the mounting holes of the
drive.
Ê Push the assembled drive with the rails into the free bay until the EasyClick
rails are locked in position.
Ê Connect the cables to the drive as described in the next section.
Ê Close the server, connect it to the mains, and switch it ON as described in
chapter "Completion" on page 31 and following.
Proceed in the reverse order for removal.
U41599-J-Z156-1-76
Installing CD/DVD/Tape Drive
Options Guide
19