Replacement Routines
Ê In case the selfsticking synthetic foil remains at the system board it should
be easy to remove it and stick it to the retaining plate again.
Ê Unpack the new system board, place it on an antistatic surface and check
the settings (for description see the Technical Manual for the system board).
1
Figure 24: Mounting the retaining plate
Ê Remove the protective foil (if available) from the retaining plate (1).
Ê Place the retaining plate on the lower surface of the system board by fitting
the threaded bolts of the plate (2) through the location holes (3) on the
system board (4). Apply slight pressure to this plate and it will stick to the
system board.
Ê Turn the system board carefully.