IMPORTANT!
The water connection instructions below are intended only for the professional installer.
●
●
DO NOT use with water that is microbiologically unsafe or of unknown quality.
●
●
WARNING – connect to potable drinkable water supply only.
●
●
DO NOT install on line pressure above 120psi (827kPa) or below 22psi (150kPa).
●
●
DO NOT use on hot water supply (100°F [38°C max.]).
●
●
AVOID contamination of pipes during installation.
●
●
Old water fittings (hose-sets) should not be reused.
●
●
The standard appliance includes a stainless braided water line hose. 1/4" copper tubing is compatible with the system, it needs to be purchased separately and must comply with local
●
●
regulations.
The shut off valve should be accessible.
●
●
Ensure the refrigerator is NOT plugged into a power supply. Locate isolating faucet for
1
water connection – cold water supply only. Tee and faucet fittings are not supplied.
Position the appliance 1.5 – 2ft. (450 – 600mm) in front of the finished enclosure. This
will allow access behind the appliance for power and water connections.
At the front of the appliance, fasten
2
the adaptor onto one end of the
braided water line hose.
Note: the adaptor is not required for
installation, if 1/4" PEX plastic tubing
is used.
20
!0
CONNECT TO WATER AND ELECTRICAL SUPPLY
1.5 – 2ft.
(450 – 600mm)
Firmly insert the tube end of the adaptor into the PLV, until the end is no longer visible.
3
Once inserted, pull gently on tubing to ensure it is locked in (refer to A).
Note: dislodge the PLV if required.
PLV
A
Secure connection by attaching the locking key in between the PLV and tube end of the
4
adaptor (refer to B).
Note: if PLV was dislodged for installation (
B
), mount PLV back into clip.
3