Installation Notes

Please take time to read through this guide before installing your Alpha-Link LIVE-R. If however you are unable to
resist that temptation, do take note of the following points:
• Full connector pin-out details are provided at the rear of the Alpha-Link LIVE-R Installation Guide.
• The nominal analogue I/O level of the Alpha-Link LIVE-R defaults to +24dBu ≈ 0dB FS – please refer to the Virtual
Switches discussion to learn how to change this.
• If interfacing Alpha-Link 8-RMP units to the unit and the chosen operating level for the Alpha-Link LIVE-R is not
+24dBu it may be necessary to set internal links to fix the input level (in blocks of 8) to +24dBu – please refer
to Appendix B for further details.
• Your Alpha-Link LIVE-R unit can be rack mounted. Whilst the unit occupies 2U of rack space in a standard 19-
inch rack, do please leave (a 1U) space above and below the unit for cooling.
• It may be necessary to change the default CLOCK SOURCE – please refer to the Clock Source Selection discussion
on page 8 for further details.
• Please turn down, switch off or disconnect any connected amplifiers before re-configuring your Alpha-Link
LIVE-R. Changing signal routing and/or clock source can potentially produce loud audible clicks.