Notes for Virtual Switches, Page Two

1. The Alpha-Link LIVE-R unit can optionally lock to one of the four AES/EBU inputs provided on AES/EBU port 'A'.
To enable one of these four inputs to be selected the first two option switches operate together. The current AES
clock input selection is shown by the status of the channel 1 and channel 2 metering LEDs.
For the Alpha-Link LIVE-R to lock to one of these inputs it requires that the sample rate converter on that input
is also bypassed – see point 3. below.
2. When the clock source is set for EXT on the front panel, this option determines if that source is an external
Wordclock signal or one of MADI or Video – either the clock signal embedded in the incoming MADI stream or
an external PAL or NTSC video sync signal, as set on Virtual Switches page three.
When locking to video it will be necessary to specify the video standard and the unit sample rate using switches
5 through 8 on Virtual Switches page three.
3. Sample rate conversion is provided on the four AES/EBU inputs on AES/EBU port 'A'. These converters can be
switched out in pairs.