Installation; Electrical Safety Warning - Solid State Logic XLogic Delta-Link MADI HD User Manual

Madi interface for digidesign pro tools hd ystems
Hide thumbs Also See for XLogic Delta-Link MADI HD:
Table of Contents

Advertisement

Installation

Voltage Selection and Fusing 
The XLogic Delta‐Link MADI HD unit has an auto‐sensing power supply that can operate on 100 – 
230V  without  adjustment.  The  MADI‐HD  power  supply  module  is  internally  fused.  If  the  fuse 
should fail for any reason the unit should be returned to Solid State Logic for repair/replacement 
as appropriate. 
 
Safety Earth Connection 
Any mains powered item of Solid State Logic equipment that is supplied with a 3‐core mains lead 
(whether connectorised or not) should always have the earth wire connected to the mains supply 
ground. This is the safety earth and grounds the  exposed metal parts of the racks and cases and 
should not be removed for any reason. 

Electrical Safety Warning

When  installing  or  servicing  any  item  of  Solid  State  Logic  equipment  with  power  applied  and 
cover is removed, HAZARDOUS CONDITIONS CAN EXIST. 
 
These hazards include:  
High voltages 
High energy stored in capacitors 
Hot component surfaces 
Any metal jewellery (watches, bracelets, neck‐chains and rings) that could inadvertently come into 
contact  with  uninsulated  parts  should  always  be  removed  before  reaching  inside  powered 
equipment. 
 
Mains Supply and Phases 
To ensure safe operation of this equipment, connect only to an ac.   
power source that contains a protective earthing (PE) conductor.   
Also,  this  equipment  is  designed  for  connection  to  single  phase  supplies  with  the  neutral 
conductor at earth potential – category TN or TT – and is fitted with a protective fuse in the live 
conductor only. It is not designed for use with live and neutral connections reversed or where the 
neutral conductor is not at earth potential (IT supplies). 
 
 
Mains cables will be coded with the following colour scheme: 
LIVE:    
Brown 
NEUTRAL:   Blue 
EARTH:  
Yellow/Green 
 
XLogic Delta-Link MADI-HD
Page 6 of 24

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents