Installation
Voltage Selection and Fusing
The XLogic Delta‐Link MADI HD unit has an auto‐sensing power supply that can operate on 100 –
230V without adjustment. The MADI‐HD power supply module is internally fused. If the fuse
should fail for any reason the unit should be returned to Solid State Logic for repair/replacement
as appropriate.
Safety Earth Connection
Any mains powered item of Solid State Logic equipment that is supplied with a 3‐core mains lead
(whether connectorised or not) should always have the earth wire connected to the mains supply
ground. This is the safety earth and grounds the exposed metal parts of the racks and cases and
should not be removed for any reason.
Electrical Safety Warning
When installing or servicing any item of Solid State Logic equipment with power applied and
cover is removed, HAZARDOUS CONDITIONS CAN EXIST.
These hazards include:
High voltages
High energy stored in capacitors
Hot component surfaces
Any metal jewellery (watches, bracelets, neck‐chains and rings) that could inadvertently come into
contact with uninsulated parts should always be removed before reaching inside powered
equipment.
Mains Supply and Phases
To ensure safe operation of this equipment, connect only to an ac.
power source that contains a protective earthing (PE) conductor.
Also, this equipment is designed for connection to single phase supplies with the neutral
conductor at earth potential – category TN or TT – and is fitted with a protective fuse in the live
conductor only. It is not designed for use with live and neutral connections reversed or where the
neutral conductor is not at earth potential (IT supplies).
Mains cables will be coded with the following colour scheme:
LIVE:
Brown
NEUTRAL: Blue
EARTH:
Yellow/Green
XLogic Delta-Link MADI-HD