System Settings and Diagnostics

Each Alpha-Link LIVE-R unit is configured by
default to work in a simple system. Many users
however may find that these defaults are not
appropriate for their setup. To cater for such
situations the default settings may be adjusted
using a set of virtual switches, accessed from
the Alpha-Link LIVE-R front panel by placing the
unit into a diagnostic mode. These virtual
switch settings are non-volatile and once saved
are retained when the unit is power cycled.

Diagnostic Mode

Hold the SAMPLE RATE and CLOCK buttons, switch the Alpha-Link LIVE-R unit on and continue to hold the buttons
for ~2 seconds to put it into diagnostic mode – indicated by a flashing STATUS LED. Diagnostic mode can be cancelled
either by power cycling the unit or by simultaneously pressing both the SAMPLE RATE and CLOCK buttons once more.
Any changes will be lost if the unit is power cycled; the internal memory is only written to and settings saved
if diagnostic mode is exited by pressing both SAMPLE RATE and CLOCK buttons. Please allow time for any
changes to be saved.

Picking a Page of Virtual Switches

Several pages of virtual switches are provided, the current page being indicated in AMBER by the lower row of meter
LEDs where the Channel 17 LED indicates Page 1, Channel 18 indicates Page 2 etc. Pressing the METERS button will
step through the available pages of which there are four for the Alpha-Link LIVE-R.
Current option settings for the
STATUS
LED
flashes
selected page
Selected page
Selected
option
11