Toro 41594 Operator's Manual page 67

Turf sprayer
Table of Contents

Advertisement

Installing the Rate Control Manifold
Valve
1. Align a 1 gasket between the flanges of the rate control
valve manifold and the pressure filter head (A of
96).
Note: If needed, loosen the mounting hardware for
the pressure filter head as needed to provide clearance.
Figure 96
1. Locknut
5. Gasket
2. Valve mount
6. Clamp
3. Flange
7. Flange
(agitation
valve)
4. Flanged-head
8. Flange (rate
bolt
2. Assemble the rate control valve manifold, gasket, and
pressure filter head with a clamp tightened hand tight
(A of
Figure
96).
3. Align a 1 gasket between the flanges of the rate control
valve and the agitation valve manifold (A of
4. Assemble the rate control valve manifold, gasket, and
agitation valve manifold with a clamp tightened hand
tight (A of
Figure
96).
9. Manifold valve
assembly
10. Socket (outlet
fitting)
11. Retainer
(pressure filter
head)
control valve)
Figure
5. Assemble the rate control valve to the valve mount with
the 2 flanged-head bolts and 2 flanged locknuts (A of
Figure
96) that you removed in step
Rate Control Manifold Valve (page 62)
Figure
nut and bolt to 1017 to 1243 N-cm (90 to 110 in-lb).
6. Assemble the outlet fitting onto the lower endcap
fitting of the manifold valve (B of
7. Secure the endcap fitting to the outlet fitting by
inserting a retainer into the socket of the outlet fitting
(B of
Figure
8. If you loosened the mounting hardware for the
pressure filter head, tighten the nut and bolt to 1978 to
2542 N-cm (175 to 225 in-lb).
Installing the Agitation Manifold Valve
1. Align the flange of the agitation valve manifold, 1
gasket, and the flange of the agitation bypass valve (A
of
Figure
Note: If needed, loosen the mounting hardware for
the master boom valve as needed to provide clearance.
96)
67
Figure
96).
97).
3
of
Removing the
and torque the
96).