Toro 41594 Operator's Manual page 61

Turf sprayer
Table of Contents

Advertisement

2.
Removing the Master Boom Manifold Valve (page
63)
3.
Cleaning the Manifold Valve (page 65)
4.
Assembling the Manifold Valve (page 66)
5.
Installing the Master Boom Manifold Valve (page
68)
6.
Installing the Valve Actuator (page 69)
To clean the 3 section valves; refer to the following
sections:
1.
Removing the Valve Actuator (page 61)
2.
Removing the Section Manifold Valve (page 64)
3.
Cleaning the Manifold Valve (page 65)
4.
Assembling the Manifold Valve (page 66)
5.
Installing the Section Manifold Valve (page 69)
6.
Installing the Valve Actuator (page 69)
Removing the Valve Actuator
1. Position the sprayer on a level surface, set the parking
brake, stop the pump, stop the engine, and remove the
key from the starter switch.
2. Remove the 3-pin connector of the valve actuator from
the 3 socket electrical connector of the sprayer harness.
3. Remove the retainer that secures the a actuator to the
manifold valve for the rate control, agitation, master
boom, or boom section valve
Note: Squeeze the 2 legs of the retainer together while
pushing it down.
Note: Retain the actuator and retainer for installation
in
Installing the Valve Actuator (page
(Figure
82).
69).
Section Valve Actuator shown (the agitation valve actuator
1. Valve actuator (section
valve shown)
2. Retainer
4. Remove the actuator from the manifold valve.
61
Figure 82
is similar)
3. Stem port