Fault Trace Configuration - Siemens HiPath 3000 Administration Manual

Hide thumbs Also See for HiPath 3000:
Table of Contents

Advertisement

3.20.2

Fault Trace Configuration

Error tracing and logging can be configured separately for all components, i. e. the services and
applications running on the OpenStage phone. The resulting files can be viewed in the WBM
web pages over the Download links.
The File size (bytes) parameter sets the maximum file size. When the maximum size is
reached, the file is deleted, and a new file is generated. The trace data is then written to the
new file. The default value is 65536.
The Trace timeout (minutes) determines when to stop tracing, i. e. writing to the trace file.
When the value is 0, no trace file will be written.
If Automatic clear before start is checked, the existing trace file will be deleted on pressing
the Submit button, and a new, empty trace file will be generated.
The log files can be downloaded by clicking on the following hyperlinks:
Download trace file
This file contains the trace data according to the settings specified for the services.
Download boot file (not present with V2)
The system messages of the booting process. With firmware version V2, these messages
will be incorparated in the syslog file (see Download syslog file underneath).
Download old/saved trace file
Normally, the trace file is saved only in the phone RAM. When the phone restarts in a con-
trolled manner, the trace file will be saved in permanent memory
Download old/saved boot file (not present with V2)
Normally, the boot file is saved only in the phone RAM. When the phone restarts in a con-
trolled manner, the boot file will be saved in permanent memory. With firmware version V2,
these messages will be incorparated in the syslog file (see Download syslog file under-
neath).
Download sci trace file
Download upgrade trace file
The trace log created during a software upgrade.
Download upgrade error file (not present with V2)
The error log created during a software upgrade.
Download exception file (not present with V2)
Download old exception file (not present with V2)
The exception file is stored permanent memory. When the file has reached its size limit, it
will be saved as old exception file, and the current exception file is emptied for future mes-
sages. The old exception file can be viewed here.
Download old trace file
The trace file is stored permanent memory. When the file has reached its size limit, it will
be saved as old trace file, and the current exception file is emptied for future messages.
The old trace file can be viewed here.
A31003-S2010-M100-18-76A9
OpenStage HFA Family, Administration Manual
administration.fm
Administration
Diagnostics
3-103