Dust-Free Environment; Anti-Static - Maipu MP2801 Installation Manual

Table of Contents

Advertisement

MP2800 Series Router Installation Manual Version 1.0

Dust-free Environment

Dust is harmful for MP2800 operation. Dust causes static absorption,
which makes the poor contact of metal pieces. Static absorption appears
especially when the temperature and humidity are lower, which affects the
device life and causes communication fault.
Dust requirements for the room:
Maximum diameter (μm)
Maximum concentration (contained
particles per m
Apart from dust, the router has strict requirements for SO2, H2S, NH3,
and Cl2 in the room, because these harmful gases speed up the eroding of
metals and the aging of some components.
The specific limitations are as follows:
Gas
SO
2
H S
2
NH
3
Cl
2

Anti-static

MP2800 router takes lots of measures in anti-static, but when the static
exceeds a certain volume, the circuits even the whole monitor are
damaged.
For router communication, static electricity originates from external
electric field of high-pressure like electricity cables and thunders, and
internal system such as floor material and chassis structure. To prevent
the damage caused by the static, do as follows:
Ensure proper equipment grounding
Maintain dustproof room
Keep suitable temperature & humidity
Wear anti-static equipment
Maipu Confidential & Proprietary Information
3
)
Maximum value (mg/m
0.2
0.006
0.05
0.01
0.5
1
5
1.4×107
7×10
3
)
3
5
5
5
2.4×10
1.3×10
Page 37 of 55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp2806Mp2816Mp2818

Table of Contents