Conventions of screen output format: Format Description Screen print Represents the output information of the screen Keywords of Screen print The red part represents the key information in the screen output Maipu Confidential & Proprietar y Information Page 2 of 80...
Page 3
Overview MP2900 Series Router Provides the router query and configuration commands. Command Manual Obtaining Docume ntation You can access the most up-to-date Maipu product documentation on the World Wide Web at www.maipu.c Technica l Support Technical supporting hotline: 400-886-8669 ...
Page 4
You can feed back your opinions and suggestions by: Email: techsupport@maipu.com Technical hotline: 400-886-8669 We appreciate your comments. Rev ision Records Version Revision Date Revised Content V1.0 2013-04-20 First formal release Maipu Confidential & Proprietar y Information Page 4 of 80...
1.1 MP2900-04-AC Appearance and Hardware Structure The chassis dimension of MP2900-04-AC is 442 mm x 380 mm x 44.2 mm (W x D x H). The front panel view of MP2900-04-AC is shown in Figure 1-1 and back panel view of MP2900-04- AC is shown in Figure 1-2.
MP2 9 0 0 - 1 4 - A C I GUR E A CK P A NEL V I EW O F 1.Ground screw 2.Power switch 3.Power socket 4. RM2B interface daughter card slot (S1 – S4) Maipu Confidential & Proprietar y Information Page 9 of 80...
The chassis dimension of MP2900-24-DC48 is 442 mm x 380 mm x 44.2 mm (W x D x H). The front panel view of MP2900-24-DC48 is shown in Figure 1-7 and the back panel view of MP2900-24- DC48 is show n in Figure 1-8. Maipu Confidential & Proprietar y Information Page 10 of 80...
Presses the button for 3 seconds and the system resets to Reset button the default setting. One USB interface with the USB2.0 standard Configuration interface, one RJ-45 connector, Console asynchronous serial port, default Maipu Confidential & Proprietar y Information Page 11 of 80...
Page 12
Flash: indicates that data is transmitted over the port. Green GE0 – GE2 Always on: indicates that the port is up. Off: indicates that the port is down. Flash: indicates that data is transmitted over the port. Maipu Confidential & Proprietar y Information Page 12 of 80...
S ER I E S R O UT ER Keep the air passage of the route unblocked during the operation. Avoid placing the device with left outlet adjacently above and below the router. Maipu Confidential & Proprietar y Information Page 13 of 80...
When the router is delivered, there is the packing list. Please confirm w hether the accessories are complete and good according to the items in the packing list. If there is damaged or loss, please contact Maipu technical staff to replace. 2.1 Check Router Running Environment The MP2900 series routers must be used indoors.
Ensure that the anti-static wrist well-grounded. The using method of the anti- Step 4: static wrist is shown in the follow ing figure. Maipu Confidential & Proprietar y Information Page 15 of 80...
Paper knife Cables: PGND cable and power cable Console cable Optional cable Equipment and instruments: Configurable termianl (a common PC or a laptop) Multimeter Maipu Confidential & Proprietar y Information Page 16 of 80...
Open the carton, remove the protection EPE, and then you can get out of the Step 3: router. Maipu Confidential & Proprietar y Information Page 17 of 80...
1U is 44.45 mm. Here, U is short for Rack Unit. Install Slide to Cabinet The slide supports the router weight. If a slide is already on the cabinet, skip this section. Maipu Confidential & Proprietar y Information Page 18 of 80...
Page 19
Then, tighten the fixed screw. The appearance and installation methods of different cabinets and slides may vary. This section is just for your reference. Goods in kind prevail. Maipu Confidential & Proprietar y Information Page 19 of 80...
Page 20
The slide (tray) bears the weight. The router is installed to the 19-inch standard cabinet, as shown in the following figure. Maipu Confidential & Proprietar y Information Page 20 of 80...
Check and ensure that the router hanging ear and cabinet are secure and well. Check and ensure that enough space is reserved around the router for heat dissipation. 3.2 Ground the Router Maipu Confidential & Proprietar y Information Page 21 of 80...
Page 22
Fire hose and lightning rod grounding of the building are not the proper grounding location; the grounding cable of the router should be connected to the engineering grounding of the equipment room. Maipu Confidential & Proprietar y Information Page 22 of 80...
Push the buckle horizontally in the OPEN arrow direction to shift the buckle for Step 3: about 2 mm. at this time, the buckle w ill become loose and slightly upsprung. Then turn over the buckle manually. Maipu Confidential & Proprietar y Information Page 23 of 80...
Page 24
A R R O W DI R ECTI O N Install the RM2B-3G interface daughter card to the router. For how to install the Step 6: interface daughter card, refer to 6.1 Change Interface Daughter Card. Maipu Confidential & Proprietar y Information Page 24 of 80...
3 - 1 2 I I GUR E N SER T TH E A NTE N NA Step 3: Rotate the 3G antenna clockwise, tighten, and fasten the antenna. Maipu Confidential & Proprietar y Information Page 25 of 80...
Page 26
The main antenna must be installed and the auxiliary antenna is optional. The 3G interface daughter card with dual a ntenna is shown in the follow ing f igure. Maipu Confidential & Proprietar y Information Page 26 of 80...
If the overload occurs, the power is cut off. 5.Automatic overload protector When the overload comes to recovery, the power resets automatically. Connects to the power in the equipment room 6.Standard socket via the power cable. Maipu Confidential & Proprietar y Information Page 27 of 80...
The POE SPD aims for the Ethernet port of the 10/100/1000M electrical interface using the RJ-45 connector. The POE surge protector specifications contain the technical parameters and the installation and maintenance instruction of the surge protector. Refer to the specifications Maipu Confidential & Proprietar y Information Page 28 of 80...
The AC power cable is connected, as shown in the follow ing figure. 3 - 1 8 C I GUR E O NN ECT TO T HE P O W ER CA B L E Maipu Confidential & Proprietar y Information Page 29 of 80...
P O W ER TER MI NA L TO THE R O UTER Rotate the screws on the both sides of the DC power cable clockwise, fasten, Step 5: and tighten the screw. Maipu Confidential & Proprietar y Information Page 30 of 80...
Check and ensure that the PE is connected correctly. Check and ensure that the power cable is connected correctly. Check and ensure that the interface daughter card is installed and well-contacted. Maipu Confidential & Proprietar y Information Page 31 of 80...
4 - 1 C I GUR E O NSO L E CA B L E For details about the inner signal connection of the Console cables, refer to Appendix E1 Console Cable. Maipu Confidential & Proprietar y Information Page 32 of 80...
Enable the PC (or laptop), select Start > All Programs > Accessories > Step 1: Communication > Hype rTerminal, and click to set up the new connection and display the interface of Connection Desc ription as shown in Figure 4-3. Maipu Confidential & Proprietar y Information Page 33 of 80...
Page 34
ER I A L I NTER F A CE P A R A METER SETTI N G After setting the serial interface parameters, click OK to enter the Step 4: HyperTerminal interface. Maipu Confidential & Proprietar y Information Page 34 of 80...
**************************************************************************** MyPower (R) Operating System Software MP2900-24 system image file (flash0: /flash/rpl-i-6.4.0(8).pck), version 6.4.0(8)(integrity), Compiled on Jan 9 2013, 04:50:54 Copyright (C) 2010 Maipu Communication Technology Co.,Ltd.All Rights Reserved. MP2900-24 Version Information System ID : 00017a455438 Hardware Model...
SFP module directly. The TX wire should be connected to the RX wire of the peer router; the RX wire should be connected to the TX wire of the peer router. Maipu Confidential & Proprietar y Information Page 37 of 80...
Page 38
Remove the dust cap of the fiber connector and rub the optical connector core Step 2: clean using the dust-free paper soaking the anhydrous alcohol. Maipu Confidential & Proprietar y Information Page 38 of 80...
Page 39
If the optical interface is not inserted with the SFP module, cover the dust cap of the optical interface. The dust cap of the optical interface is delivered with the router. The dust cap of the optical interface is installed, as shown in Figure 4-14. Maipu Confidential & Proprietar y Information Page 39 of 80...
Display as follows: MyPower (R) Operating System Software MP2900-24 system image file (flash0: /flash/rpl-i-6.4.0(8).pck), version 6.4.0(8)(integrity), Compiled on Jan 9 2013, 04:50:54 Copyright (C) 2010 Maipu Communication Technology Co.,Ltd.All Rights Reserved. MP2900-24 Version Information System ID : 00017a455438 Hardware Model...
EY F I EL D DE SCR I P TI O N O F T HE I NF O R MA TI O N DI SP L A Y ED V I A SHO W SY STE M F A N Field Description Maipu Confidential & Proprietar y Information Page 41 of 80...
The sending power of the optical module (only for the TxPower(dBm) optical module supporting the DDMI function) The receiving power of the optical module (only for the RxPower(dBm) optical module supporting the DDMI function) Maipu Confidential & Proprietar y Information Page 42 of 80...
(set the baud rate as 9600, data bit as 8, parity check as none, stop bit as 1, traffic control as none, and select the terminal emulation as Maipu Confidential & Proprietar y Information Page 43 of 80...
When the power indicator on the panel is off, it indicates that the system power is faulty. Troubleshoot the faults according to the following steps. Check and ensure that the power supply system connected by the router and Step 1: Maipu Confidential & Proprietar y Information Page 44 of 80...
You can contact the customer service via the customer service hotline and yo u can also search for help via the website or email. Customer service: 400-886-8669 Website: http://www.maipu.com E-mail: techsupport@maipu.com Maipu Confidential & Proprietar y Information Page 45 of 80...
6 - 1 L I GUR E O O SEN TH E CA P TI V E SCR EW Step 3: Pull out the interface card along the slot guide smoothly Maipu Confidential & Proprietar y Information Page 46 of 80...
Page 47
Use the Phillips screwdriver to tighten the captive screw on the interface Step 6: daughter card and fix the interface daughter card. 6 - 4 F I GUR E I X THE CA P TI V E S CR EW Maipu Confidential & Proprietar y Information Page 47 of 80...
(you can feel that the shrapnel at the bottom and top of the SFP module locks the SFP slot), as shown in the follow ing figure. Maipu Confidential & Proprietar y Information Page 48 of 80...
6.3 Dedust the Router This section describes how to dedust the MP2900 series router. The dedusting mainly refers to dedusting of the air inle t, outlet, pluggable interface Maipu Confidential & Proprietar y Information Page 49 of 80...
The dedusting process is as follows: Prepare a backup interface daughter card for the interface daughter card to be Step 1: Maipu Confidential & Proprietar y Information Page 50 of 80...
Use the dust cap to cover the unused optical interfaces on the board and pigtail. For the optical interface in using, use a dust cap to cover the optical interface and the Maipu Confidential & Proprietar y Information Page 51 of 80...
Page 52
When the laser directly radiates the human eyes, it may cause permanent injury for the human eyes. It is forbidden to use any unapproved cleaning tools or materials to clean the optical interface or the pigtail connector. Maipu Confidential & Proprietar y Information Page 52 of 80...
442 mm × 380 mm × 44.2 mm (W×D×H) A - 2 R P P ENDI X TA B L E O UTER W EI G HT Model Wight (kg) MP2900-04-AC MP2900-14-AC MP2900-24-AC MP2900-24-DC48 Maipu Confidential & Proprietar y Information Page 53 of 80...
The RM2B-4GET interface daughter card is the multi-path gigabit Ethernet signal interface card, supporting four 10Base-T/100Base-TX/1000Base-T-RJ45 Ethernet interfaces. The panel view of the RM2B-4GET card is shown in the follow ing figure. Maipu Confidential & Proprietar y Information Page 54 of 80...
Page 55
HE MEA NI NG O F TH E I NDI CA TO R O N T HE I NTER F A CE DA UG HTER CA R D Indicator Name Indicator Color Status Maipu Confidential & Proprietar y Information Page 55 of 80...
Page 56
P P ENDI X F I G UR E P P EA RA NCE O F T HE CA R D The description of the RM2B-1CE1 interface card is shwon in the following table. Maipu Confidential & Proprietar y Information Page 56 of 80...
Page 57
Always on: indicates that the link is connected. A.2.7 RM2B-1SA The RM2B-1SA interface daughter card provides one-path V.24 or V.35 communication through one SDB26 (female) interface. The protocol type is selected based on the cable. Maipu Confidential & Proprietar y Information Page 57 of 80...
Page 58
HE MEA NI NG O F THE I N DI CA TO R O N T HE I NTER F A CE DA UGH TER CA R D Indicator Name Indicator Color Status LINK/ACT Green Off: indicates that the link is not connected. Maipu Confidential & Proprietar y Information Page 58 of 80...
Page 59
I NTER F A CE DA UGHTE R CA R D Indicator Name Indicator Color Status WWAN Green Off: indicates that link is not established. Always on: indicates that the link is already Maipu Confidential & Proprietar y Information Page 59 of 80...
Page 60
The RM2B-3G-C interface daughter card needs to install the USIM card and provides the 3G communication of the CDMA2000. The panel view of the RM2B-3G-C card is shown in the follow ing figure. Maipu Confidential & Proprietar y Information Page 60 of 80...
Page 61
Flash: indicates that data is transmitted and received. RSSI Green Off: indicates no signal or weak signal. Flash: indicates the medium and low signal. Always on: indicates the strong signal. Maipu Confidential & Proprietar y Information Page 61 of 80...
P P ENDI X TA B L E I NTER F A CE A TTR I B U TES Attribute Description RJ45 Interface Interface standard G.703 · PPP Supported protocol · X.25 · HDLC · FR Maipu Confidential & Proprietar y Information Page 63 of 80...
P P ENDI X TA B L E O R K H UMI DI TY R EQ UI R E ME NTS Description Humidity Long-term work condition 5% – 85%/RH Maipu Confidential & Proprietar y Information Page 64 of 80...
Page 65
Apart from dust, the router equipment room has the strict requirements for salts, acids, and sulfides contained in the air, because these harmful gases speed up the eroding of metals and the aging of some components. Maipu Confidential & Proprietar y Information Page 65 of 80...
The low-voltage power supply system should adopt the three-phase five-wire or single- phase three-wire system. The voltage of the low-voltage power supply system is 110V/220V and the frequency is 50Hz/60Hz. Maipu Confidential & Proprietar y Information Page 66 of 80...
Page 67
P P ENDI X TA B L E P O W ER SUP P L Y R EQ UI R E M EN T Item Index –48V input voltage range –40V to –57V Maipu Confidential & Proprietar y Information Page 67 of 80...
Page 68
Overshoot ≤ DC output voltage setting value ± 5% C.2.4 DC Power Supply Suggestions Standard DC power supply system is adopted. The output voltage of the communications power system should be within the required output voltage range. Maipu Confidential & Proprietar y Information Page 68 of 80...
5 ohm (for the area with high soil resistivity, it can be raised to 10ohm). D.1.3 Router Grounding Specifications The router grounding specifications are as shown in the following table. Maipu Confidential & Proprietar y Information Page 69 of 80...
Page 70
The DC power port should be added with the surge protection circuit. Maipu Confidential & Proprietar y Information Page 70 of 80...
Page 71
The length of the protection ground wire should not exceed 45 m, but should be as short as possible. Whe n exceeding 45m, it is required that the consumer re-sets the ground bar nearby. Maipu Confidential & Proprietar y Information Page 71 of 80...
When laying the fibers, it is required that the wiring is smooth and the bundling is neat. It is required that the internal core wire is grounded before the outdoor fiber enters the indoor. The fiber cannot be stretched or bundled too tightly. Maipu Confidential & Proprietar y Information Page 72 of 80...
Page 73
P P ENDI X TA B L E ER MI TTE D F O R C E O F T HE F I B ER Force Time Tensile Force (N) Crush Force (N/100mm) Maipu Confidential & Proprietar y Information Page 73 of 80...
Page 74
I A GR A M O F R O UT ER EQ UI P O TE NTI A L CO N NE CTI O N 1. Router ground terminal 2. Router equipotential connection line 3. Ground protection cable 4. Ground bar Maipu Confidential & Proprietar y Information Page 74 of 80...
The FE Ethernet interface cable of t he MP2900 series router is an eight-core unshielded twisted cable. Port 1 and port 2 are the transmitting ends and port 3 and port 6 are the receiving ends. Maipu Confidential & Proprietar y Information Page 75 of 80...
O NNE CTI O N TA B L E O F T HE THER NE T I NTER F A CE CA B L E RJ-45 Signal Direction RJ-45 TD0+ ←→ TD0- ←→ TD1+ ←→ TD1- ←→ Maipu Confidential & Proprietar y Information Page 76 of 80...
2CE1. The other side of the cable is the standard BNC pinhead, connecting to the E1/CE1 interface of the BNC pinhead on the peer device. The view of the coaxial cable is shown in the follow ing figure. Maipu Confidential & Proprietar y Information Page 77 of 80...
For the use conditions of the product in the environme ntal protection use period, refer to the requirements for the use environment in the product manuals. Note 1: In the statement, list all components that may be configured in Maipu products. For the actual components contained in each product, please prevail in kind.