Table of Contents

Advertisement

Quick Links

MP7500 Router Installation
Manual Version 1.0
Maipu Communication Technology Co., Ltd
No. 16, Jiuxing Avenue
Hi-tech Park
Chengdu, Sichuan Province
People's Republic of China - 610041
Tel: (86) 28-85148850, 85148041
Fax: (86) 28-85148948, 85148139
URL: http://
www.maipu.com
Email:
overseas@maipu.com
Maipu Confidential & Proprietary Information
Page 1 of 62

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MP7500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Maipu MP7500

  • Page 1 MP7500 Router Installation Manual Version 1.0 Maipu Communication Technology Co., Ltd No. 16, Jiuxing Avenue Hi-tech Park Chengdu, Sichuan Province People’s Republic of China - 610041 Tel: (86) 28-85148850, 85148041 Fax: (86) 28-85148948, 85148139 URL: http:// www.maipu.com Email: overseas@maipu.com Maipu Confidential & Proprietary Information...
  • Page 2: Document History

    Maipu makes no representations or warranties with respect to this document contents and specifically disclaims any implied warranties of merchantability or fitness for any specific purpose. Further, Maipu reserves the right to revise this document and to make changes from time to time in its content without being obligated to notify any person of such revisions or changes.
  • Page 3: Maipu Feedback Form

    MP7500 Router Installation Manual Version 1.0 Maipu Feedback Form Your opinion helps us improve the quality of our product documentation and offer better services. Please fax your comments and suggestions to (86) 28-85148948 or email to overseas@maipu.com. Document Title MP7500 ROUTER INSTALLATION MANUAL VERSION 1.0...
  • Page 4: Table Of Contents

    MP7500 Router Installation Manual Version 1.0 Contents About Installation Manual .................7 Purpose .........................7 How to Get in Touch ....................7 Customer Support........................7 Documentation Support......................7 Overview.....................8 MP7500 Appearance ....................9 MP7500 Front Panel....................10 MP7500 Back Panel ....................11 MP7500 System ....................11 Modules....................
  • Page 5 MP7500 Router Installation Manual Version 1.0 RM7B-32CE1H Interface Board Connected Cable ..............27 RM7B-32CE1H Jumper Setting....................28 RM7B-32CE1H Interface Board Attributes................28 RM7B-8E1H Interface Board Panel and Indicators ..............29 RM7B-8E1H Interface Board Connected Cable ................29 RM7B-8E1H Jumper Setting....................30 RM7B-8E1H Interface Board Attributes...................30 RM7B-16E1H Interface Board Panel and Indicators ..............31 RM7B-16E1H Interface Board Connected Cable ..............31...
  • Page 6 MP7500 Router Installation Manual Version 1.0 Channelized POS High-speed Interface Board (RM7B-1CPOS-OC3H, RM7B-2CPOS-OC3H, RM7B- 4CPOS-OC3H) Cable Connection....................57 Connecting Power Supply ..................58 Cables ...................... 60 Ethernet Interface Cable..................60 Console Port Cable....................60 Maipu Confidential & Proprietary Information Page 6 of 62...
  • Page 7: About Installation Manual

    Maipu English documentation and products. Customer Support If you have problems or questions regarding your product, please contact us by e-mail at overseas@maipu.com. You can also call our Overseas Business Department over +86–28-85148850, 85148041, 85148050, 85148750, and 85148997. Documentation Support Maipu Communication Technology Co., Ltd welcomes comments and...
  • Page 8: Overview

    MP7500 Router Installation Manual Version 1.0 Overview The MP7500 router is a core aggregation router designed and developed on the lines of Advanced Telecom Computing Architecture (ATCA) for efficient large-scale WAN core aggregation and core uplink connection. It can also serve as super large-scale Internet access platform and provide two control slots, eight MIM slots, and 32-port 155M interface or 256-port E1 interface.
  • Page 9: Mp7500 Appearance

    MP7500 Router Installation Manual Version 1.0 • Provide rich software functions and be completely compatible with main routers in the industry • Adopt great cooling system to meet the standards of ATCA architecture chassis design and ensure the system stability •...
  • Page 10: Mp7500 Front Panel

    MP7500 Router Installation Manual Version 1.0 MP7500 Front Panel MP7500 front panel comprises shelf, control slot and module slot. There are system information unit, slots, lead groove and front air inlet from the top to the bottom of the shelf.
  • Page 11: Mp7500 Back Panel

    MP7500 Router Installation Manual Version 1.0 MP7500 Back Panel MP7500 back panel provides two fan slots, three power slots, one DB15 alarm interface and electrostatic terminal. MP7500 System MP7500 basic configuration and working environment: Item Description Control board type RM7B-MPU408-4GEH...
  • Page 12 MP7500 Router Installation Manual Version 1.0 Power slot Three Fan slot AC: 100-240V Input voltage DC: -40--57V 350W, supports 2+1 hot backup, supports AC or DC, but not Rating power support mixing AC and DC. When there are more than four line cards, adopt 2+1 power supply backup.
  • Page 13: Modules

    MP7500 Router Installation Manual Version 1.0 Modules MP7500 is modular router, integrating two control slots (MPU) for hot backup, eight MIM slots (LPU). The control card integrates one console port, one AUX port, one DC0 port, one USB port, one CF slot and four 10/100/1000M Ethernet interfaces.
  • Page 14: Control Card Panel & Indicator

    MP7500 Router Installation Manual Version 1.0 MPU card and LPU card both support hot swap. LPU module has ONLINE button, which is used for hot swap of LPU modules: • To un-install the running module, press the button. When the hot- swap indicator turns to flash from on, and then goes out, it means that the LPU module is un-installed successfully.
  • Page 15 MP7500 Router Installation Manual Version 1.0 Indicators: Control card SYSTEM Green light Slow flash: works normally (flash system (CPU control) frequency: 0.5Hz) indicator Off/on: The control card does not work normally MASTER Green light On: works in master mode (hardware...
  • Page 16: 4Ge Interface Connected Cable

    MP7500 Router Installation Manual Version 1.0 4GE Interface Connected Cable Ethernet interface cable of the control card adopts 8-pin non-screen twisted pair. In 10BASE-T and 100BASE-TX mode, silver plate 1 and 2 are the sending ends; silver plate 3 and 6 are the sending ends. In 1000BASE- T mode, silver plate 1, 2, 3, 4, 5, 6, 7, and 8 are all used for receiving and sending signals.
  • Page 17: Rm7B-1Atm-Oc3H Interface Board Connected Cable

    MP7500 Router Installation Manual Version 1.0 RM7B-1ATM-OC3H interface board indicators: Indicator Description On: Link connected LINK (green Off: Link not connected light) Flash: The port is configured with local loop and loopback is checked. Flash: with data receiving and sending...
  • Page 18: Rm7B-2Atm-Oc3H Interface Board Panel And Indicators

    MP7500 Router Installation Manual Version 1.0 RM7B-2ATM-OC3H Interface Board Panel and Indicators RM7B-2ATM-OC3H interface board panel: RM7B-2ATM-OC3H interface board indicators: Indicator Description The status of the first port The status of the second port LINK (green On: Link connected light)
  • Page 19: Rm7B-2Atm-Oc3H Interface Module Attributes

    MP7500 Router Installation Manual Version 1.0 RM7B-2ATM-OC3H Interface Module Attributes RM7B-2ATM-OC3H interface attributes: Attribute Description Interface type Standard dual LC optical interface Number of interfaces Interface SFP MSA standards ·ATM ·AAL5 Supported ·IP protocols ·PPP ·ATM-FR 4-port high-speed ATM Interface Board (RM7B-4ATM-OC3H) RM7B-4ATM-OC3H high-speed interface board mainly uses ATM network (155.52Mbps) to provide four optical ports with 155.52Mbps bandwidth for...
  • Page 20: Rm7B-4Atm-Oc3H Interface Board Panel And Indicators

    MP7500 Router Installation Manual Version 1.0 RM7B-4ATM-OC3H Interface Board Panel and Indicators RM7B-4ATM-OC3H interface board panel: RM7B-4ATM-OC3H interface board indicators: Indicator Description The status of the first port The status of the second port The status of the third port...
  • Page 21: Rm7B-4Atm-Oc3H Interface Module Attributes

    MP7500 Router Installation Manual Version 1.0 RM7B-4ATM-OC3H Interface Module Attributes RM7B-4ATM-OC3H interface attributes: Attribute Description Interface type Standard dual LC optical interface Number of interfaces Interface SFP MSA standards Supported protocols AAL5 ATM-FR 2-port Gigabit Ethernet Interface Board (RM7B-2GEH) RM7B-2GEH interface board provides two SFP optical interfaces. The optical interface can only work in 1000M rate.
  • Page 22: Rm7B-2Geh Interface Board Connected Cable

    MP7500 Router Installation Manual Version 1.0 RM7B-2GEH indicators: Indicator Description The status of the first port The status of the second port On: Ethernet link connected LINK (green light) Off: Ethernet link not connected Off: no data receiving and sending...
  • Page 23: Rm7B-8Ce1H Interface Board Panel And Indicators

    MP7500 Router Installation Manual Version 1.0 8-channelized E1 Interface Board (RM7B-8CE1H) The 8-channelized E1 interface board provides eight 1984K (31×64Kbps) multi-timeslots data flow receiving, sending and processing port. For CE1 interface, divide timeslot 1-31 to different groups, and each group works as one interface after binding.
  • Page 24: Rm7B-8Ce1H Jumper Setting

    MP7500 Router Installation Manual Version 1.0 RM7B-8CE1H Jumper Setting RM7B-8CE1H interface board provides internal jumper setting for interface grounding. The jumpers are located after DB40 pin connector and each port corresponds with a jumper. Jumping mode: RxShield direct grounding RxShield grounding through capacitance...
  • Page 25: Rm7B-16Ce1H Interface Board Panel And Indicators

    MP7500 Router Installation Manual Version 1.0 16-channelized E1 Interface Board (RM7B-16CE1H) The 16-channelized E1 interface board provides 16 1984K (31×64Kbps) multi-timeslots data flow receiving, sending and processing port. For CE1 interface, divide timeslot 1-31 to different groups, and each group works as one interface after binding.
  • Page 26: Rm7B-16Ce1H Jumper Setting

    MP7500 Router Installation Manual Version 1.0 RM7B-16CE1H Jumper Setting RM7B-16CE1H interface board provides internal jumper setting for interface grounding. The jumpers are located after DB40 pin connector and each port corresponds with a jumper. Jumping mode: RxShield direct grounding RxShield grounding through capacitance...
  • Page 27: Rm7B-32Ce1H Interface Board Panel And Indicators

    MP7500 Router Installation Manual Version 1.0 32-channelized E1 Interface Board (RM7B-32CE1H) The 32-channelized E1 interface board provides 32 1984K (31×64Kbps) multi-timeslots data flow receiving, sending and processing port. For CE1 interface, divide timeslot 1-31 to different groups, and each group works as one interface after binding.
  • Page 28: Rm7B-32Ce1H Jumper Setting

    MP7500 Router Installation Manual Version 1.0 RM7B-32CE1H Jumper Setting RM7B-32CE1H interface board provides internal jumper setting for interface grounding. The jumpers are located after DB40 pin connector and each port corresponds with a jumper. Jumping mode: RxShield direct grounding RxShield grounding through capacitance...
  • Page 29: Rm7B-8E1H Interface Board Panel And Indicators

    MP7500 Router Installation Manual Version 1.0 8-port Non-channelized E1 Interface Board (RM7B-8E1H) The 8-port non-channelized E1 interface board provides eight bandwidth 2.048Mbit/s ports for data transmission. E1 is the same as CE1. There are 32 timeslots, but timeslot0 of E1 can be used for transmitting data in unframed mode for 2M transparent transmissions.
  • Page 30: Rm7B-8E1H Jumper Setting

    MP7500 Router Installation Manual Version 1.0 RM7B-8E1H Jumper Setting RM7B-8E1H provides internal jumper setting for interface grounding. The jumpers are located after DB40 pin connector and each port corresponds with a jumper. Jumping mode: RxShield direct grounding RxShield grounding through capacitance...
  • Page 31: Rm7B-16E1H Interface Board Panel And Indicators

    MP7500 Router Installation Manual Version 1.0 16-port Non-channelized E1 Interface Board (RM7B-16E1H) The 16-port non-channelized E1 interface board provides 16 bandwidth 2.048Mbit/s ports for data transmission. E1 is the same as CE1. There are 32 timeslots, but timeslot0 of E1 can be used for transmitting data in unframed mode for 2M transparent transmissions.
  • Page 32: Rm7B-16E1H Jumper Setting

    MP7500 Router Installation Manual Version 1.0 RM7B-16E1H Jumper Setting RM7B-16E1H provides internal jumper setting for interface grounding. The jumpers are located after DB40 pin connector and each port corresponds with a jumper. Jumping mode: RxShield direct grounding RxShield grounding through capacitance...
  • Page 33: Rm7B-32E1H Interface Board Panel And Indicators

    MP7500 Router Installation Manual Version 1.0 32-port Non-channelized E1 Interface Board (RM7B-32E1H) The 32-port non-channelized E1 interface board provides 32 bandwidth 2.048Mbit/s ports for data transmission. E1 is the same as CE1. There are 32 timeslots, but timeslot0 of E1 can be used for transmitting data in unframed mode for 2M transparent transmissions.
  • Page 34: Rm7B-32E1H Interface Board Attributes

    MP7500 Router Installation Manual Version 1.0 Jumping mode: RxShield direct grounding RxShield grounding through capacitance RM7B-32E1H Interface Board Attributes RM7B-32E1H interface attributes: Attributes Description Interface type DB40 DB40<——>8×BNC Number of interfaces Interface standard G.703 Supported protocol ·PPP ·HDLC ·frame-relay ·virtualethernet...
  • Page 35: Rm7B-1Cpos-Oc3H Interface Board Panel And Indicators

    MP7500 Router Installation Manual Version 1.0 RM7B-1CPOS-OC3H Interface Board Panel and Indicators RM7B-1CPOS-OC3H interface board panel: 1CPOS-OC3H indicators: RM7B- Indicator Description The status of the first port On: Fiber link is connected LINK Off: Fiber link is not connected (green light) Flash: Link loopback Flash: The port has data receiving and sending.
  • Page 36: Rm7B-1Cpos-Oc3H Interface Board Attributes

    MP7500 Router Installation Manual Version 1.0 RM7B-1CPOS-OC3H Interface Board Attributes RM7B-1CPOS-OC3H interface attributes: Attributes Description Interface type Standard dual LC optical interface Number of interfaces Interface SFP MSA standard Supported ·PPP protocol ·HDLC ·Frame-relay ·virtualethernet 2-port Channelized POS High-speed Interface Board (RM7B-2CPOS-OC3H) The RM7B-2CPOS-OC3H high-speed interface board transmits up-layers data packet (transmitting rate is 155.52Mbps) by using 63-port E1 channel...
  • Page 37: Rm7B-2Cpos-Oc3H Interface Board Connected Cable

    MP7500 Router Installation Manual Version 1.0 RM7B-2CPOS-OC3H indicators: Indicator Description The status of the first port The status of the second port On: Fiber link is connected LINK Off: Fiber link is not connected (green light) Flash: Link loopback Flash: The port has data receiving and sending.
  • Page 38: Rm7B-4Cpos-Oc3H Interface Board Panel And Indicator

    MP7500 Router Installation Manual Version 1.0 4-port Channelized POS High-speed Interface Board (RM7B-4CPOS-OC3H) The RM7B-4CPOS-OC3H high-speed interface board transmits up-layers data packet (transmitting rate is 155.52Mbps) by using 63-port E1 channel or port1-12 E1 combination channel of SDH network. RM7B-4CPOS-OC3H Interface Board...
  • Page 39: Rm7B-4Cpos-Oc3H Interface Board Attributes

    ·virtualethernet Fan Module (RM7508-FANH) (Mandatory) Fan module is mandatory for MP7500 and supports hot swap. It provides mandatory ventilation to disperse the heat generated when circuit board works. It has two fan shelves (upper and lower), which are both inserted from the shelf back.
  • Page 40: Fan Module Working Process

    When only one is inserted, it works at full speed. RM7B-SIU-01 Module (Mandatory) SIU module is mandatory for MP7500. It provides LCD panel and buttons for users to check the working status of MP7500, and shows the system working status through LEDs. RM7B-SIU-01 Pane & Indicator...
  • Page 41: Ad400-1S005V Module

    MP7500 Router Installation Manual Version 1.0 AD400-1S005V Module AD400-1S005V module panel: Indicators on AD400-1S005V module: Status Description Power supply faulty Power supply normal DD400-5S005A Module DD400-5S005A module panel: Indicators on DD400-5S005A module: Status Description Power supply faulty Power supply normal Maipu Confidential &...
  • Page 42: Installation Preparation

    Environment Requirements MP7500 series routers must be used indoor. To guarantee stable use of routers and prolong the life, the application scenario must meet the following requirements.
  • Page 43: Temperature And Humidity

    MP7500 Router Installation Manual Version 1.0 Temperature and Humidity To ensure the service quality and life of MP7500 series routers, it is recommended to maintain a certain temperature and humidity in the computer lab. If the humidity in the computer lab is high for long time, it causes the poor insulation and even electricity leak of insulation materials easily.
  • Page 44: Anti-Static

    0.006 0.05 0.01 Anti-static MP7500 router takes lots of measures in anti-static, but when the static exceeds a certain volume, the circuits even the whole monitor are damaged. For router communication, static electricity originates from external electric field of high-pressure like electricity cables and thunders, and internal system such as floor material and chassis structure.
  • Page 45: Electromagnetic Environment Requirements

    • Take electromagnetic shielding methods when necessary. Anti-lightning MP7500 router takes lots of measures in anti-lightning, but when the lightning exceeds a certain volume, the router may be damaged. To prevent the damages caused by lightning, do as follows: •...
  • Page 46 MP7500 Router Installation Manual Version 1.0 Tools & Equipment Tools • Slotted point screwdriver/cross point screwdriver • Level, ruler or tapeline • Anti-static equipment Connected cables • Cables in the package Equipment • HUB or Ethernet switch • Configuring terminal (can be PC) Maipu Confidential &...
  • Page 47: System Installation

    Maipu devices are designed according to the dimension of 19-inch standard cabinet, so they can be installed and fixed normally on 19-inch standard cabinet. MP7500 router is 14U high. Before installing MP7500, reserve enough slot room. Use the level or tapeline to measure the center distance of the horizontal installation hole and net horizontal direction installation space of the cabinet.
  • Page 48 MP7500 Router Installation Manual Version 1.0 Check whether the floating nut for fixing the device is installed in the square hole of the cabinet column. If not, insert the floating nut to the square hole according to the position of the pallet or tray.
  • Page 49 • During the installation, be careful to avoid falling or hitting. Install MP7500 router to the cabinet as follows. • Step 1: Wear gloves and check whether the pallets or trays on the cabinet are fixed. Clean the pallets and trays.
  • Page 50 MP7500 Router Installation Manual Version 1.0 Maipu Confidential & Proprietary Information Page 50 of 62...
  • Page 51 MP7500 Router Installation Manual Version 1.0 Install the fan shelf as follows: • Step 1: Before installing fan shelf, ensure that the shelf is installed in the cabinet correctly and check whether the fan shelf is in good condition. •...
  • Page 52 MP7500 Router Installation Manual Version 1.0 Install the power supply module as follows: Step 1: Before installing the power supply module, ensure that the shelf is installed in the cabinet correctly and check whether the power supply module is in good condition. Place the power switch to OFF.
  • Page 53 MP7500 Router Installation Manual Version 1.0 Install the board cards as follows: • Step 1: Before installing board cards, ensure that the shelf is installed in the cabinet, and fan shelf and power supply module are installed in the shelf. During the installation, the hands cannot touch the components on the board card.
  • Page 54 MP7500 Router Installation Manual Version 1.0 Install the baffles as follows: • Step 1: Before installing baffles, ensure that the shelf is installed in the cabinet, and fan shelf and power supply module are installed in the shelf. During the installation, the hands cannot touch the components on the board card.
  • Page 55: Control Card (Rm7B-Mpu408-4Geh) Cable Connection

    MP7500 Router Installation Manual Version 1.0 Control Card (RM7B-MPU408-4GEH) Cable Connection This section describes how to connect the control card cables of MP7500 router to the network, including the router console port. Connect router console port: MP7500 router provides an EIA/TIA-232 asynchronous serial console port, through which the user can adopt the character terminal (usually it is a common PC) with RS-232 serial port to configure the router.
  • Page 56: High-Speed Atm Board Card (Rm7B-1Atm-Oc3H, Rm7B-2Atm-Oc3H, Rm7B-4Atm-Oc3H) Cable Connection

    MP7500 Router Installation Manual Version 1.0 High-speed ATM Board Card (RM7B- 1ATM-OC3H, RM7B-2ATM-OC3H, RM7B- 4ATM-OC3H) Cable Connection This section describes how to connect the high-speed ATM board card (RM7B-1ATM-OC3H, RM7B-2ATM-OC3H, RM7B-4ATM-OC3H) cable. Step 1: Insert the fiber connector to the jack of the high-speed ATM board card (RM7B-1ATM-OC3H, RM7B-2ATM-OC3H, RM7B-4ATM-OC3H) optical module.
  • Page 57: Channelized E1 Interface Board (Rm7B-8Ce1H, Rm7B-16Ce1H, Rm7B-32Ce1H) And Non- Channelized (Rm7B-8E1H, Rm7B-16E1H, Rm7B-32E1H) Cable Connection

    MP7500 Router Installation Manual Version 1.0 Channelized E1 Interface Board (RM7B- 8CE1H, RM7B-16CE1H, RM7B-32CE1H) and Non-channelized (RM7B-8E1H, RM7B-16E1H, RM7B-32E1H) Cable Connection This section describes how to connect channelized E1 interface board (RM7B-8CE1H, RM7B-16CE1H, RM7B-32CE1H) non-channelized interface board (RM7B-8E1H, RM7B-16E1H, RM7B-32E1H) cable.
  • Page 58: Connecting Power Supply

    If STATE light is off/on, it means that the channelized POS high-speed interface board does not work normally. Grounding Wire Connection The normal connection of MP7500 ground wire is the first guarantee of anti-thunder and anti-interference of the router. It is required that users must connect the ground wires correctly.
  • Page 59 MP7500 Router Installation Manual Version 1.0 Ground wire Naught wire Live wire Common power supply jack Connect the power supply as follows: • Step 1: Put the power supply switch to OFF. For AC router, connect one side of AC power supply cable to the AC power input end of the back panel of the router and another side to power supply jack (AC: 220V 50Hz/60Hz) and use the clip to lock the cable;...
  • Page 60: Cables

    Twisted-pair 4 ---- ---- Console Port Cable MP7500 console port cable is connected with PC 9-pin serial jack, and it is 8-pin non-screen cable. One side is RJ45 plug and another is DB9 (hole). RJ45 jack 5 4 3 2 1...
  • Page 61 MP7500 Router Installation Manual Version 1.0 Console port cable connection relation: RJ45 Signal Direction Length —> —> —> <— <— <— Maipu Confidential & Proprietary Information Page 61 of 62...
  • Page 62 MP7500 Router Installation Manual Version 1.0 RM7B-8/16/32CE1/RM7B-8/16/32E1 Cable CE1/E1 interface of MP7500 is 40-pin jack: DB40 (pin) Signal Signal Description Length RX1+ RX1+ RX1- Screen RX1- RX2+ RX2+ RX2- Screen RX2- Empty RX3+ RX3+ RX3- Screen RX3- RX4+ RX4+ RX4-...

Table of Contents