MP2800 Series Router Installation Manual Version 1.0
Channelized E1 Module (CE1)
Series

1-port Channelized E1 Module (1CE1)

The 1-port channelized E1 module provides multi-timeslot data flow port
with total bus transmission rate 1984K. When used as CE1 interface, it can
be divided into 1-31 timeslots, and each group works an interface after
binding.
1 CE 1 In te rfa ce M odule & Indicator
1CE1 interface module:
1-port channelized E1 module (1CE1)
1-port channelized E1 module (1CE1) indicator:
LOS
1 CE 1 Mo d ul e Connected C able
Coaxial line with BNC pin and RJ45-RJ45 connected twisted-pair.
Maipu Confidential & Proprietary Information
Lost indicator
On: Cannot check sync signal
Off: After sync