19. AF Laser Optical Axis Adjustment
Align the laser optical axis with the center of the LCD screen.
Subject
Paper which reflection rate is 18%
(1.0m from the front of the lens)(Note1)
Measurement Point
LCD screen
Measuring Instrument
Adjustment Element
Laser optical axis adjustment screw
Adjustment Tool
Hexagonal wrench
(The distance between the opposite
surfaces = 0.7mm) (Note4)
Specified Value
The part A, part B and part C of the
hologram pattern must protrude from the
rectangle. And the part A and the part C
must be about equal. (Fig. 5-1-17)
Note1: The flash (Xenon tube) is driven by a high voltage DC power
supply (Approx. 300V). There is a danger of electric shock when
the flash unit (ST1850) is handled by hand.
Note2: Background paper (J-250-130-A). Perform this adjustment in the
dark room or use a dark box.
Note3: Any light other than the laser light should not light up the plate.
Note4:
0.7mm
Note5: This adjustment should be carried out upon completion of the
following adjustments.
AF laser output adjustment
Switch setting:
1)
POWER .................................................................. CAMERA
2)
FLASH ......................................................................... OPEN
(Press FLASH ( ) button and set to the forced flash mode ( ),
and press PHOTO button.)
3)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
1
0
01
01
2
F
91
82
3
6
5B
F7
4
6
5C
A5
5
6
6
20
11
7
8
Note6: Don't turn the laser optical axis adjustment screw unnecessarily.
Procedure
Set the data.
Set the data, and press PAUSE
button.
Set the data.
Set the data.
Check that a rectangle is indicated
on the LCD screen. (Fig. 5-1-17)
Set the data, and press PAUSE
button.
Adjust the laser optical axis
adjustment screw so that the part
A and the part C of the hologram
pattern is equal. (Note6)
Check that the part A, part B and
part C of the hologram pattern
protrude from the rectangle.
DCR-PC115/PC115E/PC120BT/PC120E
Processing after Completing Adjustments:
Order Page Address Data
1
F
91
2
6
20
3
6
5B
4
6
5C
5
0
01
Caution:
High voltage
Hologram pattern
Part A
5-35
Procedure
00
Set the data, and press PAUSE
button.
00
Set the data, and press PAUSE
button.
00
Set the data.
00
Set the data.
00
Set the data.
Apply the screw locking
compound there, and lock
the laser optical axis
adjustment screw after
adjustment.
Laser optical axis
adjustment screw
Fig. 5-1-16.
Part B
Rectangle
Fig. 5-1-17.
Part C