Mechanical Shutter Adjustment; Steady Shot Check - Sony Handycam DCR-PC115 Service Manual

Digital video camera recorder
Hide thumbs Also See for Handycam DCR-PC115:
Table of Contents

Advertisement

14. Mechanical Shutter Adjustment

Adjustment Page
F
Adjustment Address
5C to 75
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to page: F, addresses: 5C to 75.
Note: Press the PAUSE button of the adjustment remote commander each
time to set the data.
Address
Data
5C
70
5D
9E
5E
A6
5F
A5
60
A8
61
20
62
A7
63
0C
64
6E
65
09
66
B5
67
07
68
5B
69
06
6A
7A
6B
05
b6C
8F
6D
2E
6E
6F
6F
4B
70
91
71
46
72
7B
73
39
74
83
75
33
3)
Select page: 0, address: 01, and set data: 00.
RadarW
RadarW
RadarW
RadarW
RadarW

15. Steady Shot Check

Precautions on the Parts Replacement
There are two types of repair parts.
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations. After replacing, re-
adjust according to the adjusting method after replacement.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Note1: Displayed data of the adjustment remote commander.
Switch setting:
1)
2)
Adjusting method:
Order Page Address Data
Note2: Don't move the camcorder.
Processing after Completing Adjustments
Order Page Address Data
5-31
DCR-PC115/PC115E/PC120BT/PC120E
RadarW
RadarW
RadarW
RadarW
RadarW
Type A: ENC03LA
Type B: ENC03LB
Subject
Arbitrary
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Specified Value
1B00 to 2500
1 : XX : XX
Display data
STEADY SHOT (Menu display) ...................................... ON
ZOOM ......................................................................... Center
1
6
04
11
2
1
3
6
04
12
4
1
1
6
04
00
Procedure
Pitch sensor check
(VM-027 board SE3450)
Set the data.
Check that the display data
(Note1) satisfies the specified
value. (Note2)
Yaw sensor check
(VM-027 board SE3451)
Set the data.
Check that the display data
(Note1) satisfies the specified
value. (Note2)
Procedure
Set the data.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Handycam pc115eHandycam pc120btHandycam pc120e

Table of Contents