[SERVICE POSITION TO CHECK THE ELECTRICAL VIEW FINDER SECTION]
Connection to Check the Electrical view finder Section
Set the Electrical view finder to the "Forced EVF back light power ON" mode and "Forced VTR power ON" mode to check
the Electrical view finder section.
Setting the "Forced VTR Power ON" mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 02 and
press the PAUSE button of the adjustment remote
commander.
01: Camera mode, 02: VTR mode
Setting the "Forced EVF Back light Power ON" mode
1) Select page: 2, address: 0E, and set data: 67.
2) Select page: 2, address: 0F, and set data: 01.
Adjustment remote
commander (RM-95)
AC IN
CPC-6 terminal board jig
(J-6082-371-A)
CPC-6 flexible jig
(J-6082-370-B)
DC-IN connector
AC power
adaptor
(88P)
VC-270 board
Mechanism deck
DCR-PC115/PC115E/PC120BT/PC120E
Exiting the "Forced VTR Power ON" mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
Exiting the "Forced EVF Back light Power ON" mode
1) Select page: 2, address: 0E, and set data: 00.
2) Select page: 2, address: 0F, and set data: 00.
(88P)
FJ-035 board
Need to
(72P)
connect it
Lens assembly
CD-349 board
2-17