Mechanical Shutter Adjustment (Dcr-Ip7Bt/Ip7E); Standard Data Input - Sony DCR-IP5 Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-IP5:
Table of Contents

Advertisement

DCR-IP5/IP5E/IP7BT/IP7E
10. Mechanical Shutter Adjustment
(DCR-IP7BT/IP7E)
Adjust the period which the mechanical shutter is closed, and
compensate the exposure.
Adjustment Page
Adjustment Address
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Input the following data to page: F, addresses: 70 to 84.
Note: Press the PAUSE button of the adjustment remote commander
each time to set the data.
Address
Data
70
BD
71
09
72
6F
73
07
74
77
75
06
76
A6
77
05
78
43
79
04
7A
E5
7B
58
7C
2B
7D
6D
7E
D9
7F
6D
80
4D
81
5D
82
D9
83
40
84
22
3) Input the following data to page: 7, addresses: 1D to 20.
Note: Press the PAUSE button of the adjustment remote commander
each time to set the data.
Address
Data
1D
7A
1E
80
1F
80
20
7F
4) Select page: 0, address: 01, and set data: 00.
F
7
70 to 84
1D to 20
11. LV Standard Data Input
Adjust the white balance reference at 3200K, and adjust the normal
coefficient of the light value.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: Refer to "11. Picture Frame Setting".
Note2: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3: This adjustment should be carried out upon completion of the F
No. & ND light quantity standard data input.
Note4: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Adjusting method:
Order Page Address Data
1
0
01
2
6
01
3
6
02
4
F
10
5
1
6
6
01
7
6
3F
8
6
01
9
6
02
Note5: The adjustment data will be automatically input to page: E, address:
1E, 1F.
Note6: The adjustment data will be automatically input to page: E, address:
46 to 49.
Processing after Completing Adjustments:
Order Page Address Data
1
6
01
2
F
10
3
6
3F
4
0
01
5-22
Clear chart (Color reproduction
adjustment frame) Note1
Display data of page 1 (Note3)
Adjustment remote commander
F
1E, 1F, 46 to 49
0FF0 to 1010
LV data
Procedure
01
Set the data.
0D
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note5)
2E
Set the data, and press PAUSE
button.
Check that the display data (Note4)
satisfies the specified value.
00
Set the data, and press PAUSE
button.
10
Set the data.
85
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note6)
Procedure
00
Set the data, and press PAUSE
button.
00
Set the data, and press PAUSE
button.
00
Set the data.
00
Set the data.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-ip5eDcr-ip7btDcr-ip7e

Table of Contents