Plena Voice Alarm System | Installation and User Instructions | System units
12 Mains power inlet - A socket to connect the
mains power source to the router (see section 4.15).
13 Ground - A connection to electrically ground the
router.
14 Firmware upgrade connector - An RS232
connector to connect a PC to upgrade the firmware
of the router.
1
Plena Voice Alarm Router
Fault Indicators
0 dB
Processor reset
Network
-6dB
Call/EMG
-20dB
Music/Spare
Ground short
Input
5
1 Channel
Booster 1
BGM/Call
Booster 2
N.C./Spare
A
Z1
Z2
Z3
Z4
Z5
Z6
100V 0 100V 0 100V 0 100V 0 100V 0 100V 0 100V 70V 0 100V
100V 0 100V 0 100V 0 100V 0 100V 0 100V 0 100V 0
B
Z1
Z2
Z3
Z4
Z5
Z6
figure 3. 1 2: Front and rear views of the router (LBB1992/00)
16 Router connector - Two RJ45 connectors to
connect a controller or another router (see section
4.6).
17 Router ID - A rotary switch to set the ID of the
router (see section 5.6).
18 External booster 1 and 2 outputs - Two XLR
sockets to connect external booster 1 and 2 (see
section 4.15.3). These socket are respectively used in
combination with the Ext booster 1/2 in pins (no. 6
and 24).
19 ??? -
Bosch Security Systems | 2004-06 | 9922 141 10371en
2
A
B
Zone1
Mains
Zone2
Zone3
Battery
Zone4
Zone5
Zone6
6
7
8
9
Override/Trigger Output
Trigger Input
Emergency
2 Channel
Z1
Z2
Z3
Z4
Z5
Z6
1
BGM/Spare
Call
24V
Booster
24V
V.O.R.
TRG1
TRG2
Failure
DC Out
Business
Booster 1 in
Call out
1
NC
NO
NC
NO
COM
24V
Z1
Z2
Z3
Z4
Z5
Z6
1
+24V-
Booster 2 in
DC In
TRG1 TRG2
Booster
24V
V.O.R.
1
Failure
DC Out
23
21
19
24
22
20
15 Configuration settings - Two DIP switches to
configure the router. A termination switch to identify
the last router in a row and a firmware upgrade
switch to enable firmware upgrading.
Zone select
Zone1
Zone2
Zone select
LBB 1992/00
2
3
4
5
6
Plena Voice Alarm Router
115-230V~,50/60Hz
10k
10k
S/N.
2
3
4
5
6
Out
2
3
4
5
6
GND
Booster 2
Booster 1
2
3
4
5
6
18
20 24V DC output -
21 Booster failure - Two pins (NC relays) to report a
booster failure.
22 TRG1/2 - Two general purpose trigger outputs.
23 Backup power inlet - An inlet to connect a back-
up power supply to the router (see section 4.15.2).
24 External booster 2 input - Two input pins to
connect external booster 2 (70V/100V). These pins
are used in combination with the XLR socket Booster
2 Out (no. 18).
3
Zone3
Zone4
Zone5
4
10
115V~
230V~
8900 199 20001
Apparatus delivered
Connected for 230V~
N663
Design & Quality
The Netherlands
Rated input power:100VA
Line fuse:T1L250V for 230V AC
T2L250V for 115V AC
Router
Termination
In
Firmware upgrade
ID
Off
Out
Warning
This apparatus must be earthde
On
1...9
Firmware Upgrade
17
16
15
14
en | 28
Alarm
Zone6
11
12
Power