Table 9-1 Normal Power Up Error Codes - Tektronix PHASER 560 Service Manual

Hide thumbs Also See for PHASER 560:
Table of Contents

Advertisement

Downloaded from
www.Manualslib.com
Normal power-up self-tests.
a problem is encountered with the image processor's expansion memory or other
options, then the information is printed on the printer's startup page. Normal
power-up tests take slightly longer than one minute to complete.
Any failure not allowing the printer to print the start page are displayed on the
printer's front panel with a two-digit hex code indicating what the error is. A
two digit hex code with the suffix "p" indicates the failure occurred during
normal power-up self test. The cause of such a failure would be the image
processor board, one of its SIMM components or the engine control board.

Table 9-1 Normal power up error codes

Code
Power-up Test
10
Image Processor CPU Interrupt
11
Instruction ROM Checksum
13
NVRAM Acknowledge
1b
PROM Data
1c
Font ROM Checksum
21
Write/Read Centronics
25
SCSI Interrupt26 W/R SCSI Register
28
W/R LCA Registers
29
W/R CDU Reg2b CDU Data Compression
2c
CDU Data Decompression
2a
DMA Address Test
2f
Network Card
1d
DRAM SIMM Configuration
31
Base DRAM Address Paths
32
Expansion DRAM Data Paths
36
SIMM1 Data Paths
37
SIMM1 Address Paths
3a
SIMM2 Data Paths
3b
SIMM2 Address Paths
47
Engine Control Board Status