Normal power-up self-tests

This test requires no paper or customer interaction. If a problem is encountered with
the image processor's expansion memory or other options, then the information is
printed on the printer's startup page. Normal power-up tests take slightly longer
than one minute to complete.
Any failure not allowing the printer to print the start page are displayed on the
printer's front panel with a two-digit hex code indicating what the error is. A two
digit hex code with the suffix "p" indicates the failure occurred during normal power-
up self test.

Normal power up error codes

Code
Power-up test
10p
Image Processor CPU Interrupt
11p
Instruction ROM Checksum
13p
NVRAM Acknowledge
1bp
PROM Data
1cp
Font ROM Checksum
21p
Write/Read Centronics
25p
SCSI Interrupt
26p
W/R SCSI Register
28p
W/R LCA Registers
29p
W/R CDU Register
2bp
CDU Data Compression
2cp
CDU Data Decompression
2ap
DMA Address Test
2fp
Network Card
1dp
DRAM DIMM Configuration
31p
Base DRAM Address Paths
32p
Expansion DRAM Data Paths
36p
DIMM1 Data Paths
37p
DIMM1 Address Paths
3ap
DIMM2 Data Paths
3bp
DIMM2 Address Paths
47p
Engine Control Board Status
Corrective action
1. Ensure that correct RAM
DIMMs, Code ROM SIMM,
SCSI card and network
card are installed
2. Reset the NVRAM
3. Replace the Code ROM
SIMM
4. Replace the RAM DIMMs
5. Replace the image
processor board
6. Replace the font SIMM (if
installed on Phaser 740)
7. Replace the image
processor to engine board
cable
8. Replace the engine control
board
Service Guide