f The projector may go into the standby status to protect the projector depending on the contents of the error.
1
Self-diagnosis result display
Displays the item check results.
[OK]: Indicates that operation is normal.
[FAILED]: Indicates that there is a problem.
[WARNING]: Indicates that there is a warning.
r [FAILED] items displayed when a problem occurs
Item
[FAN]
[FAN(R_B)]
[FAN(G)]
[FAN(PBS)]
[FAN(LAMP)]
[FAN(REAR)]
[FAN(POWER)]
[FAN(EXHAUST)]
[INTAKE AIR TEMPERATURE]
[EXHAUST AIR TEMPERATURE]
[LAMP REMAIN TIME]
[LAMP STATUS]
[APERTURE (CONTRAST-SHUTTER)]
[SHUTTER (MUTE-SHUTTER)]
[INTAKE AIR TEMP.SENSOR]
[EXHAUST AIR TEMP.SENSOR]
[BATTERY]
[AIRFLOW SENSOR]
[LENS MOUNTER]
[FILTER UNIT]
[AIR FILTER]
*1 Only for PT-EZ590, PT-EW650 and PT-EX620
[Network status] page
Click [Status] → [Network status].
The current network setting status is displayed.
122 - ENGLISH
Chapter 5 Operation of Function — Web control function
Trouble has occurred in the fan or its drive circuit. Consult your dealer.
Trouble has occurred in the R/B panel cooling fan.
Trouble has occurred in the G panel cooling fan.
Trouble has occurred in the PBS cooling fan.
Trouble has occurred in the lamp cooling fan.
Trouble has occurred in the rear fan.
Trouble has occurred in the power cooling fan.
Trouble has occurred in the exhaust fan.
The air intake temperature is too high. The projector may be used in an operating
environment where the temperature is high, such as near a heating appliance.
The exhaust air temperature is high. The air exhaust port may be blocked.
The lamp runtime has exceeded the prescribed cumulative time, and it is now time to replace
the lamp.
The lamp has failed to light.
Wait a short while for the lamp to cool off, and then turn on the power.
Trouble has occurred in the contrast shutter circuitry. Consult your dealer.
*1
Trouble has occurred in the shutter circuitry. Consult your dealer.
*1
Trouble has occurred in the sensor used to detect intake air temperature. Consult your
dealer.
Trouble has occurred in the sensor used to detect exhaust air temperature. Consult your
dealer.
Battery replacement is required. Consult your dealer.
Trouble has occurred in the sensor used to detect airflow. Consult your dealer.
Trouble has occurred in the lens mounter. Consult your dealer.
The air filter unit is not attached. Check the attachment of the air filter unit. (x page 139)
There is too much dust accumulated in the air filter unit. Turn the <MAIN POWER> switch to
<OFF> (x page 50), and clean the air filter. (x page 139)