Command Reference List - NEC PlasmaSync 50PD2 User Manual

Table of Contents

Advertisement

Appendix

Command Reference List

01.
Connect Request
02.
Running Sense
03.
Power ON
04.
Power OFF
05.
Input Switch Change
06.
COLOR TEMP Select
07.
RED Gain Data
08.
GREEN Gain Data
09.
BLUE Gain Data
10.
GAMMA Gain Data
11.
COLOR Gain Data
12.
TINT Gain Data
13.
SHARPNESS Gain Data
14.
CONTRAST Gain Data
15.
BRIGHT Gain Data
16.
V.POS Gain Data
17.
H.POS Gain Data
18.
PHASE Gain Data
19.
CLOCK Gain Data
20.
––
21.
––
22.
V-HEIGHT Gain Data
23.
H-WIDTH Gain Data
24.
TIMER SWITCH
25.
AUTO PICTURE Select
26.
RESET
27.
COLOR SYSTEM Select
28.
INPUT MODE Request
29.
SCREEN MODE Request
30.
VIDEO ADJ Request
31.
SCREEN ADJ Request
32.
COLOR SYSTEM Request
33.
FAILURE MODE Inform
34.
SET CONDITION Inform
35.
SIGNAL Inform
36.
SETTING MODE Select
37.
SCREEN MODE Select
38.
PICTURE Mute On
39.
PICTURE Mute Off
40.
MULTI MODE Select
41.
MULTI MODE Request
42.
OSM SELECT
43.
VOLUME Gain Data
44.
SOUND INPUT Select
45.
VOLUME Gain Data Request
46.
SOUND INPUT SELECT Request
47.
CONFIG MENU Select
48.
TIMER PROGRAM Setting
49.
MULTI DISP MODE Select
50.
MULTI DISP MODE Request
51.
PRESENT TIME Setting
E-50
P
M
LASMA
ONITOR
CMD1
CMD2
LEN
4FH
39H
01H
4FH
88H
00H
8FH
4EH
00H
8FH
4FH
00H
CFH
50H
01H
CFH
00H
01H
CFH
10H
04H
CFH
11H
04H
CFH
12H
04H
CFH
13H
03H
CFH
14H
03H
CFH
15H
03H
CFH
16H
03H
CFH
17H
03H
CFH
18H
03H
CFH
19H
03H
CFH
1AH
04H
CFH
1BH
03H
CFH
1CH
03H
CFH
1FH
03H
CFH
20H
03H
CFH
02H
01H
CFH
57H
02H
OFH
54H
01H
CFH
5CH
01H
0FH
41H
00H
0FH
42H
00H
0FH
45H
00H
0FH
47H
00H
0FH
4CH
00H
0FH
3FH
00H
0FH
40H
00H
0FH
3EH
00H
CFH
04H
02H
CFH
51H
01H
8FH
3CH
00H
8FH
3DH
00H
CFH
03H
02H
0FH
3BH
00H
DFH
58H
01H
CFH
21H
03H
CFH
05H
02H
0FH
46H
00H
0FH
60H
00H
CFH
06H
01H
CFH
08H
0CH
CFH
07H
02H
0FH
61H
00H
CFH
09H
0AH
01. Connect Request
Function
The external control equipment requests a communications connec-
tion from the display.
When the display has received this command, it returns an ACK to the
external control equipment and notifies that the connection is com-
pleted.
Transmission Data
4FH UA1 UA2 39H 01H 00H CKS
CKS : Checksum
ACK
0FH UA2 UA2 39H 00H CKS
02. Running Sense
Function
The external control equipment ascertains the power supply condition
of the display and then causes the display to recognize the PC CON-
TROL connection.
Transmission Data
4FH UA1 UA2 88H 00H CKS
ACK
0FH UA1 UA2 88H 01H DATA CKS
DATA:
Bit0 : Connect Condition
0 : No connection
1 : Connected
Bit1
0 : Fixed
1 : -
Bit2 : Power Status
0 : POWER ON
1 : POWER OFF(STANDBY)
Bit3
0 : Fixed
1 : –
Bit4
0 : Fixed
1 : –
Bit5
0 : Fixed
1 : –
Bit6
0 : Fixed
1 : –
Bit7
0 : Fixed
1 : –
03. Power ON
Function
The external control equipment switches on the power of the display.
Transmission Data
8FH UA1 UA2 4EH 00H CKS
ACK
The display returns the following ACK when the power is switched on:
2FH UA1 UA2 4EH 00H CKS
04. Power OFF
Function
The external control equipment switches off the power of the display.
Transmission Data
8FH UA1 UA2 4FH 00H CKS
ACK
The display returns the following ACK when the power is switched off:
2FH UA1 UA2 4FH 00H CKS

Advertisement

Table of Contents
loading

Table of Contents