INDICATIONS ON THE DISPLAY (D1)
ALARM INDICATIONS
Both travel limits have cut in
The letter
, will appear on the display and the system remains blocked.
The warning lights will flash for a three second period which is repeated
every six seconds. The only way to solve this problem is to check the travel
limits for obstacles or damage and then restart the system.
• Once the alarm condition terminates the program will automatically reset
and the programmer will consider the gate to be completely closed. It
will not therefore accept closing commands.
Parameters loaded from EEPROM are wrong
The letter
, will flash on the display and the system remains blocked.
The only way to solve this situation is to enter the program mode and
reprogram the system. If the problem persists after reprogramming, the
problem regards the EEPROM (incorrect memorising). Switch off the power
to the system, after a few seconds switch it back on and then reprogram
the system.
Time programming mode block
( caused by: TB, FTC_I, FTC_S )
FUNCTION INDICATIONS
defining the system configuration
waiting period between successive
programming stages
deceleration time setting (value 1)
level 1 electrical input sensor
work time programming
opening stage
block
reclosing pause (only if enabled)
closing stage
updating the electrical input monitoring system
MANUAL OPERATION MODE
This can be used to close the gate (or open it) under the direct control
of the operator (in this mode the electrical input monitoring system is
excluded.
The aim of this command is to make installation easier and to allow you to
have the gate completely closed before starting the programming procedure.
In this mode the Led "L3" (marked "UPL") will remain lit.
Attention: do not keep the motor under tension when the door
has reached the travel limit as this will blow the motor power
supply protective fuse. Should this occur replace the fuse with
another with the same rating.
• Closing manoeuvre
This is obtained by pressing the button "SEL".
The motor will block in the closing direction due to:
- releasing the "SEL" button (takes you out of the "manual operation
mode").
- activating the blocking button "TB": to move the door again you must
first release the "SEL" button and then press it again.
- activating the closing direction travel limit (if installed): pressing the "SEL"
button will not cause the door to close, but it will switch the courtesy
light on.
• Opening manoeuvre
This is obtained by pressing the button "SEL", and then the "PROG" button
straight away. The motor will block in the opening direction due to:
- releasing both buttons (takes you out of the "manual operation mode").
- activating the blocking button "TB": to move the door again you must
first release both buttons and then press them again.
- activating the opening direction travel limit.
• Travel direction inversion
If the door is closing: to enable an opening manoeuvre:
- press the "PROG" button
If the door is opening: to enable a closing manoeuvre:
- release the "PROG" button
• Courtesy light
The courtesy light remains on all the time while in the "manual operation
mode"; it also lights up when an opening or closing command is given
but the travel limit blocks the command.
FUNCTION MODES
1) Automatic
Selected by enabling automatic reclosing (programming step 2, number
not flashing). When the gate is completely closed the opening command
will start a complete cycle which will end with automatic reclosing and the
courtesy light switching off.
Automatic reclosing starts after the programmed pause period has elapsed
when the opening cycle has been completed or straight away after the
intervention of a photoelectric cell (the intervention of a photoelectric cell
causes the pause time to be reset). During the pause time the symbol
flash on the display and pressing the blocking button during this period will
stop automatic reclosing and consequently stop the display from flashing.
The intervention of mechanical travel limits will block the gate. The indicator
light remains lit until the closing manoeuvre has terminated.
Note: The courtesy light switches on automatically each time a movement
command is given either by control button or by radio. The intervention
of a photoelectric cell during reclosing has no effect on the timing of the
courtesy light.
2) Semiautomatic
Selected by disabling automatic reclosing (programming step 2, number
flashing). Work cycle control using separate opening and closing com-
mands. When the gate has reached the completely open position the
system will wait until it receives a closing command either via an external
control button or via radio control, before completing the cycle.
The activation of one of the opening travel limit causes the gate to stop
and the termination of the opening. Starting from the end of the opening
manoeuvre the courtesy light will switch off after the set period has elapsed.
The indicator light remains lit if the gate is not completely closed.