Status Indicators - Sharp MX-B200 Operation Manual

Digital multifunctional system
Hide thumbs Also See for MX-B200:
Table of Contents

Advertisement

STATUS INDICATORS

When the following indicators light up or blink on the operation panel or the following
alphanumeric codes appear in the display, solve the problem immediately referring
to both the table below and the relevant page.
Be sure to use only genuine SHARP parts and supplies.
Indication
Developer
replacement
required indicator
Toner cartridge
replacement
required indicator
Misfeed indicator Blinking
Maintenance
indicator
SPF misfeed
indicator
Power save indicator is
steadily lit.
The paper tray indicator is
blinking.
"CH" is blinking in the display.
"CH" is steadily lit in the
display.
"OP" is blinking in the display.
"P" is blinking in the display.
A letter and a number appear
alternately.
Downloaded From ManualsPrinter.com Manuals
Developer is required. Contact your authorised
Steadily lit
service representative as soon as possible.
Replacement of toner cartridge will be needed
Steadily lit
soon. Prepare a new cartridge.
Toner cartridge must be replaced. Replace it with
Blinking
a new one.
A misfeed has occurred. Remove the misfed paper
referring to the description of "MISFEED REMOVAL".
The lower side cover may be open. If so, close it.
Service by an authorised SHARP service
Steadily lit
technician is required.
Steadily lit When the document feeder cover is open.
An original misfeed has occurred in the SPF. Remove
Blinking
the misfed originals referring to the description of
"E: Misfeed in the SPF (Peripheral device)".
The unit is in the preheat mode. Press any key to
cancel the preheat mode.
The unit is in the auto power shut-off mode.
Press the start (
power shut-off mode.
The paper tray is not pushed in correctly, or there
is no paper in the tray. Push the tray all the way
in or load paper in the tray.
The Toner cartridge is not installed. Check if the
cartridge is installed.
Push the cartridge in until it locks securely in place.
Side cover is open. Close the side cover securely
by pressing the round projections near the side
cover open button.
This appears if it is detected that the original
cover/SPF is open when copying is started.
Completely close the original cover/SPF, or
press the start (
Depending on the colour and the density of the
original, "OP" blinking may appear even when
the original cover/SPF is closed. In such a case,
press the start key again to make a copy.
The paper tray or multi-bypass tray is empty.
Load paper.
A misfeed has occurred in the paper tray or
multi-bypass tray. Remove the misfed paper.
The unit will not function. Turn the power switch
off, remove the power cord from the outlet, and
contact your authorised service representative.
79
Cause and remedy
) key to cancel the auto
) key again.
Page
86
66
66
80
83
86
84
61
61
Start
Guide
10, 12
9
80

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents