8.2 Condensation.
Condensation inside the tank may contain the oil residues. Dispose of the condensation in an
environmentally friendly way. DO NOT put it down the drain or onto the ground.
8.2.1 You MUST remove condensed water is daily.
8.2.2 This can be achieved by opening the condensation drain plug at the bottom of the
compressor.
8.3 Safety valve.
8.3.1 The safety valve has been factory set to the maximum pressure of the tank. DO NOT
attempt to adjust or remove. If there is a problem you must get it checked - contact your dealer
for advice.
8.4 Oil Level.
9.4.1 The oil level (6) must be visible between the red oil level and the top edge of the oil
level indicator. Recommended oil: SAE 15W/40 or its equivalent.
9.4.2 The initial oil level should be checked after 100 hours of operation.
9.4.3 After every 500 hours of operation you MUST drain the oil and refill with new oil.
8.5 Oil change.
9.5.1 Turn off the compressor and disconnect from the electrical supply.
9.5.2 Release all air pressure from the air tank.
9.5.3 Place a suitable container underneath the compressor to catch the oil.
9.5.4 Unscrew the oil drain bolt on the compressor pump so that the oil runs out.
9.5.5 If the oil does not completely run out, we recommend the compressor is leant over in
the direction of the drain plug.
9.5.6 Once all of the old oil has been drained, you can replace the oil drain bolt.
9.5.7 Pour new oil into the oil filler hole (page 11 picture 6), until the oil level in the visible
glass (6) has reached the red point. Once the correct level of oil has been put in replace
the oil plug.
9.5.8 DO NOT put unused oil down any drain or onto the ground.
8.6 Cleaning the air filter.
9.6.1 The filter prevents dust and dirt from getting into the machine.
9.6.2 It is necessary to clean these filters at least every 300 hours.
9.6.3 Blocked air filter significantly reduces the output of the compressor. 9.6.4 Remove
the filter from the compressor by following 6.2.
9.6.5 Clean air filter by blowing it clean with the air compressor at a low pressure (3
bars).
8.7 Storage.
Disconnect the compressor from the electrical supply by switching off and unplugging the supply
plug.
9.7.1 Purge compressor of all compressed air.
9.7.2 Store compressor in a secure location away from children and vulnerable persons.
9.7.3 Keep compressor in a clean and dry location. It must be kept upright.
Page 13