Disposal & Recycling; Troubleshooting - Hyundai HY2524 User Manual

Table of Contents

Advertisement

9. DISPOSAL & RECYLING.
9.1 Do not dispose of electric equipment together with household waste material! In observance
of European Directive 2012/19/EC on waste electrical and electronic equipment and its
implementation in accordance with national law, electric equipment that have reached the end of
their life must be collected separately and returned to an environmentally compatible recycling
facility. If electrical appliances are disposed of in landfills or dumps hazardous substances can leak
into the groundwater and get into the food chain, damaging your health and well-being.
19.2 For further information on the disposal of this product, please contact your dealer or your
nearest domestic waste collection service.
9.3 Reduce – Reuse - Recycle unwanted materials instead of disposing of them as
waste. All tools, accessories and packaging should be sorted, taken to a recycling
centre and disposed of in a manner which is compatible with the environment.
9.4 When the product is no longer required, it must be disposed of in a manner
which is compatible with the environment.

10. TROUBLESHOOTING.

Problems
Compressor does not run.
Compressor runs but has
no pressure.
Compressor is running,
pressure is displayed on
the gauge, but tools do
not run.
Reasons
1. Voltage cuts off.
2. The main voltage is too low.
3. External temperature is too low.
4. Motor overheats.
1. The valve (18) leaks
2. The seal is broken.
3. The condensation drain plug
(4) has become loose.
1. Hose connections leak.
2. Quick release coupling leak.
3. The pressure is set too low
Page 14
Solutions
1. Check cable, plug, fuse and
outlet.
2. Avoid the long extension
cords. Use the cable with the
sufficient wire cross section.
3. Not operate below 5 ℃
4. Cooling down the motor
may eliminate the failure.
1. Replace check valve.
2. Get broken seal
replaced by a specialist.
3. Tighten the screw by hands.
Check the seals on the screw
and replace it if necessary.
1. Check the compressed air
hose and tool, replace them if
necessary.
2. Check the quick release
connections
and replace them if necessary.
3. Increase the pressure
regulator adjustment knob.
Check for hose leak between
regulator and tool.
Rev 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents